Selection and testing of 2000 photomultiplier tubes for the CMS-HF forward calorimeter

The CMS-HF forward calorimeter has specific requirements for the construction and the operation of the detector. The phototubes suggested by several manufacturers were tested and Hamamatsu R7525HA photomultiplier tube conformed best to these requirements. About 2000 PMTs were needed in the HF calori...

Descripción completa

Detalles Bibliográficos
Autores principales: Gülmez, E, Akgun, U, Anderson, E W, Ayan, A S, Brücken, P, Duru, F, Mestvirishvili, A, Miller, M, Olson, J, Önel, Y M, Schmidt, I, Winn, D
Lenguaje:eng
Publicado: 2004
Materias:
Acceso en línea:http://cds.cern.ch/record/816708
_version_ 1780905427389644800
author Gülmez, E
Akgun, U
Anderson, E W
Ayan, A S
Brücken, P
Duru, F
Mestvirishvili, A
Miller, M
Olson, J
Önel, Y M
Schmidt, I
Winn, D
author_facet Gülmez, E
Akgun, U
Anderson, E W
Ayan, A S
Brücken, P
Duru, F
Mestvirishvili, A
Miller, M
Olson, J
Önel, Y M
Schmidt, I
Winn, D
author_sort Gülmez, E
collection CERN
description The CMS-HF forward calorimeter has specific requirements for the construction and the operation of the detector. The phototubes suggested by several manufacturers were tested and Hamamatsu R7525HA photomultiplier tube conformed best to these requirements. About 2000 PMTs were needed in the HF calorimeter. The timing, dark current, and relative gain values of these 2000 phototubes were measured and organized into a database. Single photoelectron spectrum resolution, absolute gain versus high voltage, and the lifetime were measured on a small sample. Except a few phototubes with unacceptably high dark currents, all the tubes were well within the specifications. (3 refs) .
id cern-816708
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2004
record_format invenio
spelling cern-8167082019-09-30T06:29:59Zhttp://cds.cern.ch/record/816708engGülmez, EAkgun, UAnderson, E WAyan, A SBrücken, PDuru, FMestvirishvili, AMiller, MOlson, JÖnel, Y MSchmidt, IWinn, DSelection and testing of 2000 photomultiplier tubes for the CMS-HF forward calorimeterDetectors and Experimental TechniquesThe CMS-HF forward calorimeter has specific requirements for the construction and the operation of the detector. The phototubes suggested by several manufacturers were tested and Hamamatsu R7525HA photomultiplier tube conformed best to these requirements. About 2000 PMTs were needed in the HF calorimeter. The timing, dark current, and relative gain values of these 2000 phototubes were measured and organized into a database. Single photoelectron spectrum resolution, absolute gain versus high voltage, and the lifetime were measured on a small sample. Except a few phototubes with unacceptably high dark currents, all the tubes were well within the specifications. (3 refs) .oai:cds.cern.ch:8167082004
spellingShingle Detectors and Experimental Techniques
Gülmez, E
Akgun, U
Anderson, E W
Ayan, A S
Brücken, P
Duru, F
Mestvirishvili, A
Miller, M
Olson, J
Önel, Y M
Schmidt, I
Winn, D
Selection and testing of 2000 photomultiplier tubes for the CMS-HF forward calorimeter
title Selection and testing of 2000 photomultiplier tubes for the CMS-HF forward calorimeter
title_full Selection and testing of 2000 photomultiplier tubes for the CMS-HF forward calorimeter
title_fullStr Selection and testing of 2000 photomultiplier tubes for the CMS-HF forward calorimeter
title_full_unstemmed Selection and testing of 2000 photomultiplier tubes for the CMS-HF forward calorimeter
title_short Selection and testing of 2000 photomultiplier tubes for the CMS-HF forward calorimeter
title_sort selection and testing of 2000 photomultiplier tubes for the cms-hf forward calorimeter
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/816708
work_keys_str_mv AT gulmeze selectionandtestingof2000photomultipliertubesforthecmshfforwardcalorimeter
AT akgunu selectionandtestingof2000photomultipliertubesforthecmshfforwardcalorimeter
AT andersonew selectionandtestingof2000photomultipliertubesforthecmshfforwardcalorimeter
AT ayanas selectionandtestingof2000photomultipliertubesforthecmshfforwardcalorimeter
AT bruckenp selectionandtestingof2000photomultipliertubesforthecmshfforwardcalorimeter
AT duruf selectionandtestingof2000photomultipliertubesforthecmshfforwardcalorimeter
AT mestvirishvilia selectionandtestingof2000photomultipliertubesforthecmshfforwardcalorimeter
AT millerm selectionandtestingof2000photomultipliertubesforthecmshfforwardcalorimeter
AT olsonj selectionandtestingof2000photomultipliertubesforthecmshfforwardcalorimeter
AT onelym selectionandtestingof2000photomultipliertubesforthecmshfforwardcalorimeter
AT schmidti selectionandtestingof2000photomultipliertubesforthecmshfforwardcalorimeter
AT winnd selectionandtestingof2000photomultipliertubesforthecmshfforwardcalorimeter