Cargando…

General gamma-radiation test of TGC detectors

The TGC detectors are expected to provide the Muon trigger for the ATLAS detector in the forward region of the ATLAS Muon Spectrometer. The TGC detectors have to provide a trigger signal within 25 ns of the LHC accelerator bunch spacing, with an efficiency exceeding 95%, while exposed to an effectiv...

Descripción completa

Detalles Bibliográficos
Autor principal: Smakhtin, V P
Lenguaje:eng
Publicado: 2004
Materias:
Acceso en línea:http://cds.cern.ch/record/818310
_version_ 1780905464357191680
author Smakhtin, V P
author_facet Smakhtin, V P
author_sort Smakhtin, V P
collection CERN
description The TGC detectors are expected to provide the Muon trigger for the ATLAS detector in the forward region of the ATLAS Muon Spectrometer. The TGC detectors have to provide a trigger signal within 25 ns of the LHC accelerator bunch spacing, with an efficiency exceeding 95%, while exposed to an effective)photon and neutron background ranging from 30 to 150 Hz/cm/sup 2/. In order to test TGC detectors in high rate environment every detector was irradiated at 2500 Cu Co-60 source in Radiation Facility of Weizmann Institute of Science at nominal operating voltage and at photon rate several times above the expected background. This radiation test was succeeded in diagnostics of the hot spots inside detectors. The present publication refers to the test results of 800 TGC detectors produced in the Weizmann Institute of Science. (1 refs).
id cern-818310
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2004
record_format invenio
spelling cern-8183102019-09-30T06:29:59Zhttp://cds.cern.ch/record/818310engSmakhtin, V PGeneral gamma-radiation test of TGC detectorsDetectors and Experimental TechniquesThe TGC detectors are expected to provide the Muon trigger for the ATLAS detector in the forward region of the ATLAS Muon Spectrometer. The TGC detectors have to provide a trigger signal within 25 ns of the LHC accelerator bunch spacing, with an efficiency exceeding 95%, while exposed to an effective)photon and neutron background ranging from 30 to 150 Hz/cm/sup 2/. In order to test TGC detectors in high rate environment every detector was irradiated at 2500 Cu Co-60 source in Radiation Facility of Weizmann Institute of Science at nominal operating voltage and at photon rate several times above the expected background. This radiation test was succeeded in diagnostics of the hot spots inside detectors. The present publication refers to the test results of 800 TGC detectors produced in the Weizmann Institute of Science. (1 refs).oai:cds.cern.ch:8183102004
spellingShingle Detectors and Experimental Techniques
Smakhtin, V P
General gamma-radiation test of TGC detectors
title General gamma-radiation test of TGC detectors
title_full General gamma-radiation test of TGC detectors
title_fullStr General gamma-radiation test of TGC detectors
title_full_unstemmed General gamma-radiation test of TGC detectors
title_short General gamma-radiation test of TGC detectors
title_sort general gamma-radiation test of tgc detectors
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/818310
work_keys_str_mv AT smakhtinvp generalgammaradiationtestoftgcdetectors