Cargando…
Vacuum phototriodes for the CMS electromagnetic calorimeter endcap
The measurement of scintillation light from the lead tungstate crystals of the CMS ECAL poses a substantial technical challenge, particularly in the endcap regions, where the radiation levels are highest. The photodetectors must be fast, sensitive, radiation-hard, and operate with significant intern...
Autores principales: | , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2004
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/TNS.2004.836053 http://cds.cern.ch/record/818314 |
_version_ | 1780905465219121152 |
---|---|
author | Bell, K W Brown, R M Cockerill, D J A Flower, P S Hobson, P R Kennedy, B W Lintern, A L Selby, C S Sharif, O Sproston, M Williams, J H |
author_facet | Bell, K W Brown, R M Cockerill, D J A Flower, P S Hobson, P R Kennedy, B W Lintern, A L Selby, C S Sharif, O Sproston, M Williams, J H |
author_sort | Bell, K W |
collection | CERN |
description | The measurement of scintillation light from the lead tungstate crystals of the CMS ECAL poses a substantial technical challenge, particularly in the endcap regions, where the radiation levels are highest. The photodetectors must be fast, sensitive, radiation-hard, and operate with significant internal gain in a magnetic field of 4 Tesla. The measured performance characteristics of the first batches of series production vacuum phototriodes (VPT), developed to satisfy the needs of CMS, will be described. (3 refs). |
id | cern-818314 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2004 |
record_format | invenio |
spelling | cern-8183142019-09-30T06:29:59Zdoi:10.1109/TNS.2004.836053http://cds.cern.ch/record/818314engBell, K WBrown, R MCockerill, D J AFlower, P SHobson, P RKennedy, B WLintern, A LSelby, C SSharif, OSproston, MWilliams, J HVacuum phototriodes for the CMS electromagnetic calorimeter endcapDetectors and Experimental TechniquesThe measurement of scintillation light from the lead tungstate crystals of the CMS ECAL poses a substantial technical challenge, particularly in the endcap regions, where the radiation levels are highest. The photodetectors must be fast, sensitive, radiation-hard, and operate with significant internal gain in a magnetic field of 4 Tesla. The measured performance characteristics of the first batches of series production vacuum phototriodes (VPT), developed to satisfy the needs of CMS, will be described. (3 refs).oai:cds.cern.ch:8183142004 |
spellingShingle | Detectors and Experimental Techniques Bell, K W Brown, R M Cockerill, D J A Flower, P S Hobson, P R Kennedy, B W Lintern, A L Selby, C S Sharif, O Sproston, M Williams, J H Vacuum phototriodes for the CMS electromagnetic calorimeter endcap |
title | Vacuum phototriodes for the CMS electromagnetic calorimeter endcap |
title_full | Vacuum phototriodes for the CMS electromagnetic calorimeter endcap |
title_fullStr | Vacuum phototriodes for the CMS electromagnetic calorimeter endcap |
title_full_unstemmed | Vacuum phototriodes for the CMS electromagnetic calorimeter endcap |
title_short | Vacuum phototriodes for the CMS electromagnetic calorimeter endcap |
title_sort | vacuum phototriodes for the cms electromagnetic calorimeter endcap |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1109/TNS.2004.836053 http://cds.cern.ch/record/818314 |
work_keys_str_mv | AT bellkw vacuumphototriodesforthecmselectromagneticcalorimeterendcap AT brownrm vacuumphototriodesforthecmselectromagneticcalorimeterendcap AT cockerilldja vacuumphototriodesforthecmselectromagneticcalorimeterendcap AT flowerps vacuumphototriodesforthecmselectromagneticcalorimeterendcap AT hobsonpr vacuumphototriodesforthecmselectromagneticcalorimeterendcap AT kennedybw vacuumphototriodesforthecmselectromagneticcalorimeterendcap AT linternal vacuumphototriodesforthecmselectromagneticcalorimeterendcap AT selbycs vacuumphototriodesforthecmselectromagneticcalorimeterendcap AT sharifo vacuumphototriodesforthecmselectromagneticcalorimeterendcap AT sprostonm vacuumphototriodesforthecmselectromagneticcalorimeterendcap AT williamsjh vacuumphototriodesforthecmselectromagneticcalorimeterendcap |