Cargando…

Impact of metal overhang and guard ring techniques on breakdown voltage of Si strip sensors - 2003 IEEE nuclear science symposium, medical imaging conference, and workshop of room-temperature semiconductor detectors

The importance of Si sensors in high-energy physics (HEP) experiments can hardly be overemphasized. However, the high luminosity and the high radiation level in the future HEP experiments, like Large Hadron Collider (LHC), has posed a serious challenge to the fabrication of Si detectors. For the saf...

Descripción completa

Detalles Bibliográficos
Autores principales: Ranjan, K, Bjardwaj, A, Namrata, S, Chatterji, S, Srivastava-Ajay, K, Kumar, A, Jha, Manoj Kumar, Shivpuri, R K
Lenguaje:eng
Publicado: 2004
Materias:
Acceso en línea:http://cds.cern.ch/record/818324
_version_ 1780905467206172672
author Ranjan, K
Bjardwaj, A
Namrata, S
Chatterji, S
Srivastava-Ajay, K
Kumar, A
Jha, Manoj Kumar
Shivpuri, R K
author_facet Ranjan, K
Bjardwaj, A
Namrata, S
Chatterji, S
Srivastava-Ajay, K
Kumar, A
Jha, Manoj Kumar
Shivpuri, R K
author_sort Ranjan, K
collection CERN
description The importance of Si sensors in high-energy physics (HEP) experiments can hardly be overemphasized. However, the high luminosity and the high radiation level in the future HEP experiments, like Large Hadron Collider (LHC), has posed a serious challenge to the fabrication of Si detectors. For the safe operation over the full LHC lifetime, detectors are required to sustain very high voltage operation, well exceeding the bias voltage needed to full deplete the heavily irradiated Si sensors. Thus, the main effort in the development of Si sensors is concentrated on a design that avoids p-n junction breakdown at operational biases. Among various proposed techniques, Field-limiting Ring (FLR) (or guard ring) and Metal-Overhang (MO) are technologically simple and are suitable for vertical devices. Since high-voltage planar Si junctions are of great importance in the HEP experiments, it is very interesting to compare these two aforementioned techniques for achieving the maximum breakdown voltage under optimal conditions. In the present work, the breakdown performance of metal-overhang and field-limiting ring techniques is compared for various values of junction depth and fixed oxide charge under similar conditions using two dimensional device simulation program TMA-MEDICI. (10 refs).
id cern-818324
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2004
record_format invenio
spelling cern-8183242019-09-30T06:29:59Zhttp://cds.cern.ch/record/818324engRanjan, KBjardwaj, ANamrata, SChatterji, SSrivastava-Ajay, KKumar, AJha, Manoj KumarShivpuri, R KImpact of metal overhang and guard ring techniques on breakdown voltage of Si strip sensors - 2003 IEEE nuclear science symposium, medical imaging conference, and workshop of room-temperature semiconductor detectorsDetectors and Experimental TechniquesThe importance of Si sensors in high-energy physics (HEP) experiments can hardly be overemphasized. However, the high luminosity and the high radiation level in the future HEP experiments, like Large Hadron Collider (LHC), has posed a serious challenge to the fabrication of Si detectors. For the safe operation over the full LHC lifetime, detectors are required to sustain very high voltage operation, well exceeding the bias voltage needed to full deplete the heavily irradiated Si sensors. Thus, the main effort in the development of Si sensors is concentrated on a design that avoids p-n junction breakdown at operational biases. Among various proposed techniques, Field-limiting Ring (FLR) (or guard ring) and Metal-Overhang (MO) are technologically simple and are suitable for vertical devices. Since high-voltage planar Si junctions are of great importance in the HEP experiments, it is very interesting to compare these two aforementioned techniques for achieving the maximum breakdown voltage under optimal conditions. In the present work, the breakdown performance of metal-overhang and field-limiting ring techniques is compared for various values of junction depth and fixed oxide charge under similar conditions using two dimensional device simulation program TMA-MEDICI. (10 refs).oai:cds.cern.ch:8183242004
spellingShingle Detectors and Experimental Techniques
Ranjan, K
Bjardwaj, A
Namrata, S
Chatterji, S
Srivastava-Ajay, K
Kumar, A
Jha, Manoj Kumar
Shivpuri, R K
Impact of metal overhang and guard ring techniques on breakdown voltage of Si strip sensors - 2003 IEEE nuclear science symposium, medical imaging conference, and workshop of room-temperature semiconductor detectors
title Impact of metal overhang and guard ring techniques on breakdown voltage of Si strip sensors - 2003 IEEE nuclear science symposium, medical imaging conference, and workshop of room-temperature semiconductor detectors
title_full Impact of metal overhang and guard ring techniques on breakdown voltage of Si strip sensors - 2003 IEEE nuclear science symposium, medical imaging conference, and workshop of room-temperature semiconductor detectors
title_fullStr Impact of metal overhang and guard ring techniques on breakdown voltage of Si strip sensors - 2003 IEEE nuclear science symposium, medical imaging conference, and workshop of room-temperature semiconductor detectors
title_full_unstemmed Impact of metal overhang and guard ring techniques on breakdown voltage of Si strip sensors - 2003 IEEE nuclear science symposium, medical imaging conference, and workshop of room-temperature semiconductor detectors
title_short Impact of metal overhang and guard ring techniques on breakdown voltage of Si strip sensors - 2003 IEEE nuclear science symposium, medical imaging conference, and workshop of room-temperature semiconductor detectors
title_sort impact of metal overhang and guard ring techniques on breakdown voltage of si strip sensors - 2003 ieee nuclear science symposium, medical imaging conference, and workshop of room-temperature semiconductor detectors
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/818324
work_keys_str_mv AT ranjank impactofmetaloverhangandguardringtechniquesonbreakdownvoltageofsistripsensors2003ieeenuclearsciencesymposiummedicalimagingconferenceandworkshopofroomtemperaturesemiconductordetectors
AT bjardwaja impactofmetaloverhangandguardringtechniquesonbreakdownvoltageofsistripsensors2003ieeenuclearsciencesymposiummedicalimagingconferenceandworkshopofroomtemperaturesemiconductordetectors
AT namratas impactofmetaloverhangandguardringtechniquesonbreakdownvoltageofsistripsensors2003ieeenuclearsciencesymposiummedicalimagingconferenceandworkshopofroomtemperaturesemiconductordetectors
AT chatterjis impactofmetaloverhangandguardringtechniquesonbreakdownvoltageofsistripsensors2003ieeenuclearsciencesymposiummedicalimagingconferenceandworkshopofroomtemperaturesemiconductordetectors
AT srivastavaajayk impactofmetaloverhangandguardringtechniquesonbreakdownvoltageofsistripsensors2003ieeenuclearsciencesymposiummedicalimagingconferenceandworkshopofroomtemperaturesemiconductordetectors
AT kumara impactofmetaloverhangandguardringtechniquesonbreakdownvoltageofsistripsensors2003ieeenuclearsciencesymposiummedicalimagingconferenceandworkshopofroomtemperaturesemiconductordetectors
AT jhamanojkumar impactofmetaloverhangandguardringtechniquesonbreakdownvoltageofsistripsensors2003ieeenuclearsciencesymposiummedicalimagingconferenceandworkshopofroomtemperaturesemiconductordetectors
AT shivpurirk impactofmetaloverhangandguardringtechniquesonbreakdownvoltageofsistripsensors2003ieeenuclearsciencesymposiummedicalimagingconferenceandworkshopofroomtemperaturesemiconductordetectors