Advances in fast multi-GEM based detector operation for high-rate charged-particle triggering

In this paper we summarize the results obtained in an R&D work performed in the period 2000-2003 within the LHCb Collaboration to develop a triple-GEM based detector for the inner region of the first muon station. Since the information coming from this detector will he used at the L0 trigger lev...

Descripción completa

Detalles Bibliográficos
Autores principales: Alfonsi, M, Bencivenni, G, De Simone, P, Murtas, F, Poli-Lener, M, Bonivento, W, Cardini, A, Deplano, C, Pinci, D, Raspino, D, Saitta, B
Lenguaje:eng
Publicado: 2004
Materias:
Acceso en línea:http://cds.cern.ch/record/818342
Descripción
Sumario:In this paper we summarize the results obtained in an R&D work performed in the period 2000-2003 within the LHCb Collaboration to develop a triple-GEM based detector for the inner region of the first muon station. Since the information coming from this detector will he used at the L0 trigger level, many studies were performed in order to optimize its time resolution. By using CF/sub 4/-based gas-mixtures a time resolution of 4.5 ns RMS was obtained, which translates in efficiencies higher than 96 % in a 20 ns time window for a large operating region. Moreover, measurements of discharge probability per incident charged particle with a high intensity pion/proton beam for these gas mixture are also reported. All these results show that triple-GEM detectors can he used for triggering in the LHCb Muon Detector. Preliminary results on a global aging test performed with a 25 kCi /sup 60/Co source are also reported and compared to other aging tests performed with X-rays and hadron beams. (5 refs).