Cargando…

The status of the construction and the performance of the ATLAS liquid argon electromagnetic calorimeters

The construction of the ATLAS liquid argon electromagnetic calorimeters is about to be completed The barrel calorimeter and the first end cap are inserted in their cryostats. The quality control performed during the production has resulted in only a very small fraction of malfunctioning channels, ~0...

Descripción completa

Detalles Bibliográficos
Autor principal: Lund-Jensen, B
Lenguaje:eng
Publicado: 2004
Materias:
Acceso en línea:http://cds.cern.ch/record/818348
_version_ 1780905471593414656
author Lund-Jensen, B
author_facet Lund-Jensen, B
author_sort Lund-Jensen, B
collection CERN
description The construction of the ATLAS liquid argon electromagnetic calorimeters is about to be completed The barrel calorimeter and the first end cap are inserted in their cryostats. The quality control performed during the production has resulted in only a very small fraction of malfunctioning channels, ~0.1 %o., and a low constant term in the energy resolution. Several modules of the calorimeter and their corresponding presampler sectors have been tested in electron beams and their energy resolution has been shown to be within the ATLAS requirements. The local constant term is better than 0.4% for all measured cells and the global constant term which includes the cell to cell response variation is less than 0.7%. (3 refs).
id cern-818348
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2004
record_format invenio
spelling cern-8183482019-09-30T06:29:59Zhttp://cds.cern.ch/record/818348engLund-Jensen, BThe status of the construction and the performance of the ATLAS liquid argon electromagnetic calorimetersDetectors and Experimental TechniquesThe construction of the ATLAS liquid argon electromagnetic calorimeters is about to be completed The barrel calorimeter and the first end cap are inserted in their cryostats. The quality control performed during the production has resulted in only a very small fraction of malfunctioning channels, ~0.1 %o., and a low constant term in the energy resolution. Several modules of the calorimeter and their corresponding presampler sectors have been tested in electron beams and their energy resolution has been shown to be within the ATLAS requirements. The local constant term is better than 0.4% for all measured cells and the global constant term which includes the cell to cell response variation is less than 0.7%. (3 refs).oai:cds.cern.ch:8183482004
spellingShingle Detectors and Experimental Techniques
Lund-Jensen, B
The status of the construction and the performance of the ATLAS liquid argon electromagnetic calorimeters
title The status of the construction and the performance of the ATLAS liquid argon electromagnetic calorimeters
title_full The status of the construction and the performance of the ATLAS liquid argon electromagnetic calorimeters
title_fullStr The status of the construction and the performance of the ATLAS liquid argon electromagnetic calorimeters
title_full_unstemmed The status of the construction and the performance of the ATLAS liquid argon electromagnetic calorimeters
title_short The status of the construction and the performance of the ATLAS liquid argon electromagnetic calorimeters
title_sort status of the construction and the performance of the atlas liquid argon electromagnetic calorimeters
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/818348
work_keys_str_mv AT lundjensenb thestatusoftheconstructionandtheperformanceoftheatlasliquidargonelectromagneticcalorimeters
AT lundjensenb statusoftheconstructionandtheperformanceoftheatlasliquidargonelectromagneticcalorimeters