Validation of GEANT3 simulation studies with a dual-head PMT ClearPET TM prototype
The ClearPET TM project is proposed by working groups of the Crystal Clear Collaboration (CCC) to develop a 2/sup nd/ generation high performance small animal positron emission tomograph (PET). High sensitivity and high spatial resolution is foreseen for the ClearPET TM camera by using a phoswich ar...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2004
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/818486 |
_version_ | 1780905481156427776 |
---|---|
author | Ziemons, K Heinrichs, U Streun, M Pietrzyk, U |
author_facet | Ziemons, K Heinrichs, U Streun, M Pietrzyk, U |
author_sort | Ziemons, K |
collection | CERN |
description | The ClearPET TM project is proposed by working groups of the Crystal Clear Collaboration (CCC) to develop a 2/sup nd/ generation high performance small animal positron emission tomograph (PET). High sensitivity and high spatial resolution is foreseen for the ClearPET TM camera by using a phoswich arrangement combining mixed lutetium yttrium aluminum perovskite (LuYAP:Ce) and lutetium oxyorthosilicate (LSO) scintillating crystals. Design optimizations for the first photomultiplier tube (PMT) based ClearPET camera are done with a Monte-Carlo simulation package implemented on GEANT3 (CERN, Geneva, Switzerland). A dual-head prototype has been built to test the frontend electronics and was used to validate the implementation of the GEANT3 simulation tool. Multiple simulations were performed following the experimental protocols to measure the intrinsic resolution and the sensitivity profile in axial and radial direction. Including a mean energy resolution of about 27.0% the simulated intrinsic resolution is about (1.41+or-0.11)mm compared to the measured of (1.48+or-0.06)mm. The simulated sensitivity profiles show a mean square deviation of 12.6% in axial direction and 3.6% in radial direction. Satisfactorily these results are representative for all designs and confirm the scanner geometry. (9 refs). |
id | cern-818486 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2004 |
record_format | invenio |
spelling | cern-8184862019-09-30T06:29:59Zhttp://cds.cern.ch/record/818486engZiemons, KHeinrichs, UStreun, MPietrzyk, UValidation of GEANT3 simulation studies with a dual-head PMT ClearPET TM prototypeHealth Physics and Radiation EffectsThe ClearPET TM project is proposed by working groups of the Crystal Clear Collaboration (CCC) to develop a 2/sup nd/ generation high performance small animal positron emission tomograph (PET). High sensitivity and high spatial resolution is foreseen for the ClearPET TM camera by using a phoswich arrangement combining mixed lutetium yttrium aluminum perovskite (LuYAP:Ce) and lutetium oxyorthosilicate (LSO) scintillating crystals. Design optimizations for the first photomultiplier tube (PMT) based ClearPET camera are done with a Monte-Carlo simulation package implemented on GEANT3 (CERN, Geneva, Switzerland). A dual-head prototype has been built to test the frontend electronics and was used to validate the implementation of the GEANT3 simulation tool. Multiple simulations were performed following the experimental protocols to measure the intrinsic resolution and the sensitivity profile in axial and radial direction. Including a mean energy resolution of about 27.0% the simulated intrinsic resolution is about (1.41+or-0.11)mm compared to the measured of (1.48+or-0.06)mm. The simulated sensitivity profiles show a mean square deviation of 12.6% in axial direction and 3.6% in radial direction. Satisfactorily these results are representative for all designs and confirm the scanner geometry. (9 refs).oai:cds.cern.ch:8184862004 |
spellingShingle | Health Physics and Radiation Effects Ziemons, K Heinrichs, U Streun, M Pietrzyk, U Validation of GEANT3 simulation studies with a dual-head PMT ClearPET TM prototype |
title | Validation of GEANT3 simulation studies with a dual-head PMT ClearPET TM prototype |
title_full | Validation of GEANT3 simulation studies with a dual-head PMT ClearPET TM prototype |
title_fullStr | Validation of GEANT3 simulation studies with a dual-head PMT ClearPET TM prototype |
title_full_unstemmed | Validation of GEANT3 simulation studies with a dual-head PMT ClearPET TM prototype |
title_short | Validation of GEANT3 simulation studies with a dual-head PMT ClearPET TM prototype |
title_sort | validation of geant3 simulation studies with a dual-head pmt clearpet tm prototype |
topic | Health Physics and Radiation Effects |
url | http://cds.cern.ch/record/818486 |
work_keys_str_mv | AT ziemonsk validationofgeant3simulationstudieswithadualheadpmtclearpettmprototype AT heinrichsu validationofgeant3simulationstudieswithadualheadpmtclearpettmprototype AT streunm validationofgeant3simulationstudieswithadualheadpmtclearpettmprototype AT pietrzyku validationofgeant3simulationstudieswithadualheadpmtclearpettmprototype |