Cargando…
Performance of multigap RFC detectors in the HARP experiment
A time-of-flight system based on 46 multigap glass resistive plate chambers has operated for 2 years in the HARP experiment at the CERN PS. The system covers an area of 10m**2 and comprises 368 readout, channels. Systematic checks of the RFC performance are presented as well as preliminary results o...
Autores principales: | , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2004
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2004.07.030 http://cds.cern.ch/record/818550 |
_version_ | 1780905490633457664 |
---|---|
author | Barr, G Dedovich, D De Min, A De Santo, A Dydak, Friedrich Koreshev, V Linssen, Lucie Pattison, C Robbins, S Wotschack, J |
author_facet | Barr, G Dedovich, D De Min, A De Santo, A Dydak, Friedrich Koreshev, V Linssen, Lucie Pattison, C Robbins, S Wotschack, J |
author_sort | Barr, G |
collection | CERN |
description | A time-of-flight system based on 46 multigap glass resistive plate chambers has operated for 2 years in the HARP experiment at the CERN PS. The system covers an area of 10m**2 and comprises 368 readout, channels. Systematic checks of the RFC performance are presented as well as preliminary results on its particle identification capabilities. |
id | cern-818550 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2004 |
record_format | invenio |
spelling | cern-8185502019-09-30T06:29:59Zdoi:10.1016/j.nima.2004.07.030http://cds.cern.ch/record/818550engBarr, GDedovich, DDe Min, ADe Santo, ADydak, FriedrichKoreshev, VLinssen, LuciePattison, CRobbins, SWotschack, JPerformance of multigap RFC detectors in the HARP experimentDetectors and Experimental TechniquesA time-of-flight system based on 46 multigap glass resistive plate chambers has operated for 2 years in the HARP experiment at the CERN PS. The system covers an area of 10m**2 and comprises 368 readout, channels. Systematic checks of the RFC performance are presented as well as preliminary results on its particle identification capabilities.oai:cds.cern.ch:8185502004 |
spellingShingle | Detectors and Experimental Techniques Barr, G Dedovich, D De Min, A De Santo, A Dydak, Friedrich Koreshev, V Linssen, Lucie Pattison, C Robbins, S Wotschack, J Performance of multigap RFC detectors in the HARP experiment |
title | Performance of multigap RFC detectors in the HARP experiment |
title_full | Performance of multigap RFC detectors in the HARP experiment |
title_fullStr | Performance of multigap RFC detectors in the HARP experiment |
title_full_unstemmed | Performance of multigap RFC detectors in the HARP experiment |
title_short | Performance of multigap RFC detectors in the HARP experiment |
title_sort | performance of multigap rfc detectors in the harp experiment |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/j.nima.2004.07.030 http://cds.cern.ch/record/818550 |
work_keys_str_mv | AT barrg performanceofmultigaprfcdetectorsintheharpexperiment AT dedovichd performanceofmultigaprfcdetectorsintheharpexperiment AT demina performanceofmultigaprfcdetectorsintheharpexperiment AT desantoa performanceofmultigaprfcdetectorsintheharpexperiment AT dydakfriedrich performanceofmultigaprfcdetectorsintheharpexperiment AT koreshevv performanceofmultigaprfcdetectorsintheharpexperiment AT linssenlucie performanceofmultigaprfcdetectorsintheharpexperiment AT pattisonc performanceofmultigaprfcdetectorsintheharpexperiment AT robbinss performanceofmultigaprfcdetectorsintheharpexperiment AT wotschackj performanceofmultigaprfcdetectorsintheharpexperiment |