A high-voltage test for the ATLAS RPC qualification
The RPC production sequence for the ATLAS experiment includes a specific test of current absorption at the operating point, which concerns the RPC "gas volumes", namely the bare detectors not yet assembled with the read-out panels and the mechanical support structures. The test, which is c...
Autores principales: | , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2004
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2004.07.027 http://cds.cern.ch/record/818552 |
_version_ | 1780905491071762432 |
---|---|
author | Aielli, G Camarri, P Cardarelli, R Di Ciaccio, A Di Simone, A Liberti, B Santonico, R |
author_facet | Aielli, G Camarri, P Cardarelli, R Di Ciaccio, A Di Simone, A Liberti, B Santonico, R |
author_sort | Aielli, G |
collection | CERN |
description | The RPC production sequence for the ATLAS experiment includes a specific test of current absorption at the operating point, which concerns the RPC "gas volumes", namely the bare detectors not yet assembled with the read-out panels and the mechanical support structures. The test, which is carried out at the production site, consists of two phases. The gas volumes are initially conditioned with pure argon, keeping the voltage constant just above the breakdown value of about 2 kV. The final test, performed after the volumes have undergone inner surface varnishing with linseed oil, is based on the measurement of the current-voltage characteristics with the binary operating gas, C//2H//2F//4/i-C//4H//1//0 = 95/5. The results presented here concern 45% of the total foreseen production. |
id | cern-818552 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2004 |
record_format | invenio |
spelling | cern-8185522019-09-30T06:29:59Zdoi:10.1016/j.nima.2004.07.027http://cds.cern.ch/record/818552engAielli, GCamarri, PCardarelli, RDi Ciaccio, ADi Simone, ALiberti, BSantonico, RA high-voltage test for the ATLAS RPC qualificationDetectors and Experimental TechniquesThe RPC production sequence for the ATLAS experiment includes a specific test of current absorption at the operating point, which concerns the RPC "gas volumes", namely the bare detectors not yet assembled with the read-out panels and the mechanical support structures. The test, which is carried out at the production site, consists of two phases. The gas volumes are initially conditioned with pure argon, keeping the voltage constant just above the breakdown value of about 2 kV. The final test, performed after the volumes have undergone inner surface varnishing with linseed oil, is based on the measurement of the current-voltage characteristics with the binary operating gas, C//2H//2F//4/i-C//4H//1//0 = 95/5. The results presented here concern 45% of the total foreseen production.oai:cds.cern.ch:8185522004 |
spellingShingle | Detectors and Experimental Techniques Aielli, G Camarri, P Cardarelli, R Di Ciaccio, A Di Simone, A Liberti, B Santonico, R A high-voltage test for the ATLAS RPC qualification |
title | A high-voltage test for the ATLAS RPC qualification |
title_full | A high-voltage test for the ATLAS RPC qualification |
title_fullStr | A high-voltage test for the ATLAS RPC qualification |
title_full_unstemmed | A high-voltage test for the ATLAS RPC qualification |
title_short | A high-voltage test for the ATLAS RPC qualification |
title_sort | high-voltage test for the atlas rpc qualification |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1016/j.nima.2004.07.027 http://cds.cern.ch/record/818552 |
work_keys_str_mv | AT aiellig ahighvoltagetestfortheatlasrpcqualification AT camarrip ahighvoltagetestfortheatlasrpcqualification AT cardarellir ahighvoltagetestfortheatlasrpcqualification AT diciaccioa ahighvoltagetestfortheatlasrpcqualification AT disimonea ahighvoltagetestfortheatlasrpcqualification AT libertib ahighvoltagetestfortheatlasrpcqualification AT santonicor ahighvoltagetestfortheatlasrpcqualification AT aiellig highvoltagetestfortheatlasrpcqualification AT camarrip highvoltagetestfortheatlasrpcqualification AT cardarellir highvoltagetestfortheatlasrpcqualification AT diciaccioa highvoltagetestfortheatlasrpcqualification AT disimonea highvoltagetestfortheatlasrpcqualification AT libertib highvoltagetestfortheatlasrpcqualification AT santonicor highvoltagetestfortheatlasrpcqualification |