Performance of the Monitoring Light Source for the CMS Lead Tungstate Crystal Calorimeter
Light monitoring will play a crucial role in maintaining energy resolution for the CMS lead tungstate crystal calorimeter at LHC. In last several years, a laser based monitoring light source was designed and constructed at Caltech, and was installed and commissioned at CERN. This paper presents the...
Autores principales: | , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2005
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/825587 |
_version_ | 1780905665794932736 |
---|---|
author | Bailleux, David Zhang, Liyuan Bornheim, Adolf Zhu, Kejun Zhu, Ren-yuan |
author_facet | Bailleux, David Zhang, Liyuan Bornheim, Adolf Zhu, Kejun Zhu, Ren-yuan |
author_sort | Bailleux, David |
collection | CERN |
description | Light monitoring will play a crucial role in maintaining energy resolution for the CMS lead tungstate crystal calorimeter at LHC. In last several years, a laser based monitoring light source was designed and constructed at Caltech, and was installed and commissioned at CERN. This paper presents the design of the CMS ECAL monitoring light source and its performance during beam test. Issues related to the monitoring precision are discussed. |
id | cern-825587 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2005 |
record_format | invenio |
spelling | cern-8255872019-09-30T06:29:59Zhttp://cds.cern.ch/record/825587engBailleux, DavidZhang, LiyuanBornheim, AdolfZhu, KejunZhu, Ren-yuanPerformance of the Monitoring Light Source for the CMS Lead Tungstate Crystal CalorimeterDetectors and Experimental TechniquesLight monitoring will play a crucial role in maintaining energy resolution for the CMS lead tungstate crystal calorimeter at LHC. In last several years, a laser based monitoring light source was designed and constructed at Caltech, and was installed and commissioned at CERN. This paper presents the design of the CMS ECAL monitoring light source and its performance during beam test. Issues related to the monitoring precision are discussed.CMS-CR-2005-001oai:cds.cern.ch:8255872005-01-14 |
spellingShingle | Detectors and Experimental Techniques Bailleux, David Zhang, Liyuan Bornheim, Adolf Zhu, Kejun Zhu, Ren-yuan Performance of the Monitoring Light Source for the CMS Lead Tungstate Crystal Calorimeter |
title | Performance of the Monitoring Light Source for the CMS Lead Tungstate Crystal Calorimeter |
title_full | Performance of the Monitoring Light Source for the CMS Lead Tungstate Crystal Calorimeter |
title_fullStr | Performance of the Monitoring Light Source for the CMS Lead Tungstate Crystal Calorimeter |
title_full_unstemmed | Performance of the Monitoring Light Source for the CMS Lead Tungstate Crystal Calorimeter |
title_short | Performance of the Monitoring Light Source for the CMS Lead Tungstate Crystal Calorimeter |
title_sort | performance of the monitoring light source for the cms lead tungstate crystal calorimeter |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/825587 |
work_keys_str_mv | AT bailleuxdavid performanceofthemonitoringlightsourceforthecmsleadtungstatecrystalcalorimeter AT zhangliyuan performanceofthemonitoringlightsourceforthecmsleadtungstatecrystalcalorimeter AT bornheimadolf performanceofthemonitoringlightsourceforthecmsleadtungstatecrystalcalorimeter AT zhukejun performanceofthemonitoringlightsourceforthecmsleadtungstatecrystalcalorimeter AT zhurenyuan performanceofthemonitoringlightsourceforthecmsleadtungstatecrystalcalorimeter |