Evaluation of a fast PLC module in prospect of the LHC beam interlock system
The LHC Beam Interlock system requires a controller performing a simple matrix function to collect the different beam dump requests. To satisfy the expected safety level of the Interlock, the system should be robust and reliable. The PLC is a promising candidate to fulfil both aspects but too slow t...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2005
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/845141 |
_version_ | 1780906797693927424 |
---|---|
author | Zaera-Sanz, Manuel |
author_facet | Zaera-Sanz, Manuel |
author_sort | Zaera-Sanz, Manuel |
collection | CERN |
description | The LHC Beam Interlock system requires a controller performing a simple matrix function to collect the different beam dump requests. To satisfy the expected safety level of the Interlock, the system should be robust and reliable. The PLC is a promising candidate to fulfil both aspects but too slow to meet the expected response time which is of the order of mseconds. Siemens has introduced a “so called” fast module (FM352-5 Boolean Processor) that provides independent and extremely fast control of a process within a larger control system using an onboard processor, a Field Programmable Gate Array (FPGA), to execute code in parallel which results in extremely fast scan times. It is interesting to investigate its features and to evaluate it as a possible candidate for the beam interlock system. This note publishes the results of this study. As well, this note could be useful for other applications requiring fast processing using a PLC. |
id | cern-845141 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2005 |
record_format | invenio |
spelling | cern-8451412019-09-30T06:29:59Zhttp://cds.cern.ch/record/845141engZaera-Sanz, ManuelEvaluation of a fast PLC module in prospect of the LHC beam interlock systemAccelerators and Storage RingsThe LHC Beam Interlock system requires a controller performing a simple matrix function to collect the different beam dump requests. To satisfy the expected safety level of the Interlock, the system should be robust and reliable. The PLC is a promising candidate to fulfil both aspects but too slow to meet the expected response time which is of the order of mseconds. Siemens has introduced a “so called” fast module (FM352-5 Boolean Processor) that provides independent and extremely fast control of a process within a larger control system using an onboard processor, a Field Programmable Gate Array (FPGA), to execute code in parallel which results in extremely fast scan times. It is interesting to investigate its features and to evaluate it as a possible candidate for the beam interlock system. This note publishes the results of this study. As well, this note could be useful for other applications requiring fast processing using a PLC.AB-Note-2005-029CERN-AB-Note-2005-029oai:cds.cern.ch:8451412005-06-24 |
spellingShingle | Accelerators and Storage Rings Zaera-Sanz, Manuel Evaluation of a fast PLC module in prospect of the LHC beam interlock system |
title | Evaluation of a fast PLC module in prospect of the LHC beam interlock system |
title_full | Evaluation of a fast PLC module in prospect of the LHC beam interlock system |
title_fullStr | Evaluation of a fast PLC module in prospect of the LHC beam interlock system |
title_full_unstemmed | Evaluation of a fast PLC module in prospect of the LHC beam interlock system |
title_short | Evaluation of a fast PLC module in prospect of the LHC beam interlock system |
title_sort | evaluation of a fast plc module in prospect of the lhc beam interlock system |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/845141 |
work_keys_str_mv | AT zaerasanzmanuel evaluationofafastplcmoduleinprospectofthelhcbeaminterlocksystem |