Cargando…

A Cosmic Ray Measurement Facility for ATLAS Muon Chambers

Monitored Drift Tube (MDT) chambers will constitute the large majority of precision detectors in the Muon Spectrometer of the ATLAS experiment at the Large Hadron Collider at CERN. For commissioning and calibration of MDT chambers, a Cosmic Ray Measurement Facility is in operation at Munich Universi...

Descripción completa

Detalles Bibliográficos
Autores principales: Biebel, O., Binder, M., Boutemeur, M., Brandt, A., Dubbert, J., Duckeck, G., Elmsheuser, J., Fiedler, F., Hertenberger, R., Kortner, O., Nunnemann, T., Rauscher, F., Schaile, D., Schieferdecker, P., Staude, A., Stiller, W., Strohmer, R., Vertesi, R.
Lenguaje:eng
Publicado: 2003
Materias:
Acceso en línea:http://cds.cern.ch/record/852200
_version_ 1780906998314827776
author Biebel, O.
Binder, M.
Boutemeur, M.
Brandt, A.
Dubbert, J.
Duckeck, G.
Elmsheuser, J.
Fiedler, F.
Hertenberger, R.
Kortner, O.
Nunnemann, T.
Rauscher, F.
Schaile, D.
Schieferdecker, P.
Staude, A.
Stiller, W.
Strohmer, R.
Vertesi, R.
author_facet Biebel, O.
Binder, M.
Boutemeur, M.
Brandt, A.
Dubbert, J.
Duckeck, G.
Elmsheuser, J.
Fiedler, F.
Hertenberger, R.
Kortner, O.
Nunnemann, T.
Rauscher, F.
Schaile, D.
Schieferdecker, P.
Staude, A.
Stiller, W.
Strohmer, R.
Vertesi, R.
author_sort Biebel, O.
collection CERN
description Monitored Drift Tube (MDT) chambers will constitute the large majority of precision detectors in the Muon Spectrometer of the ATLAS experiment at the Large Hadron Collider at CERN. For commissioning and calibration of MDT chambers, a Cosmic Ray Measurement Facility is in operation at Munich University. The objectives of this facility are to test the chambers and on-chamber electronics, to map the positions of the anode wires within the chambers with the precision needed for standalone muon momentum measurement in ATLAS, and to gain experience in the operation of the chambers and on-line calibration procedures. Until the start of muon chamber installation in ATLAS, 88 chambers built at the Max Planck Institute for Physics in Munich have to be commissioned and calibrated. With a data taking period of one day individual wire positions can be measured with an accuracy of 8.3 micrometers in the chamber plane and 27 micrometers in the direction perpendicular to that plane.
id cern-852200
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2003
record_format invenio
spelling cern-8522002023-03-14T17:05:44Zhttp://cds.cern.ch/record/852200engBiebel, O.Binder, M.Boutemeur, M.Brandt, A.Dubbert, J.Duckeck, G.Elmsheuser, J.Fiedler, F.Hertenberger, R.Kortner, O.Nunnemann, T.Rauscher, F.Schaile, D.Schieferdecker, P.Staude, A.Stiller, W.Strohmer, R.Vertesi, R.A Cosmic Ray Measurement Facility for ATLAS Muon ChambersOther Fields of PhysicsMonitored Drift Tube (MDT) chambers will constitute the large majority of precision detectors in the Muon Spectrometer of the ATLAS experiment at the Large Hadron Collider at CERN. For commissioning and calibration of MDT chambers, a Cosmic Ray Measurement Facility is in operation at Munich University. The objectives of this facility are to test the chambers and on-chamber electronics, to map the positions of the anode wires within the chambers with the precision needed for standalone muon momentum measurement in ATLAS, and to gain experience in the operation of the chambers and on-line calibration procedures. Until the start of muon chamber installation in ATLAS, 88 chambers built at the Max Planck Institute for Physics in Munich have to be commissioned and calibrated. With a data taking period of one day individual wire positions can be measured with an accuracy of 8.3 micrometers in the chamber plane and 27 micrometers in the direction perpendicular to that plane.Monitored Drift Tube (MDT) chambers will constitute the large majority of precision detectors in the Muon Spectrometer of the ATLAS experiment at the Large Hadron Collider at CERN. For commissioning and calibration of MDT chambers, a Cosmic Ray Measurement Facility is in operation at Munich University. The objectives of this facility are to test the chambers and on-chamber electronics, to map the positions of the anode wires within the chambers with the precision needed for standalone muon momentum measurement in ATLAS, and to gain experience in the operation of the chambers and on-line calibration procedures. Until the start of muon chamber installation in ATLAS, 88 chambers built at the Max Planck Institute for Physics in Munich have to be commissioned and calibrated. With a data taking period of one day individual wire positions can be measured with an accuracy of 8.3 micrometers in the chamber plane and 27 micrometers in the direction perpendicular to that plane.physics/0307147LMU-ETP-2003-01ATL-MUON-2004-004LMU-ETP-2003-01oai:cds.cern.ch:8522002003-07-30
spellingShingle Other Fields of Physics
Biebel, O.
Binder, M.
Boutemeur, M.
Brandt, A.
Dubbert, J.
Duckeck, G.
Elmsheuser, J.
Fiedler, F.
Hertenberger, R.
Kortner, O.
Nunnemann, T.
Rauscher, F.
Schaile, D.
Schieferdecker, P.
Staude, A.
Stiller, W.
Strohmer, R.
Vertesi, R.
A Cosmic Ray Measurement Facility for ATLAS Muon Chambers
title A Cosmic Ray Measurement Facility for ATLAS Muon Chambers
title_full A Cosmic Ray Measurement Facility for ATLAS Muon Chambers
title_fullStr A Cosmic Ray Measurement Facility for ATLAS Muon Chambers
title_full_unstemmed A Cosmic Ray Measurement Facility for ATLAS Muon Chambers
title_short A Cosmic Ray Measurement Facility for ATLAS Muon Chambers
title_sort cosmic ray measurement facility for atlas muon chambers
topic Other Fields of Physics
url http://cds.cern.ch/record/852200
work_keys_str_mv AT biebelo acosmicraymeasurementfacilityforatlasmuonchambers
AT binderm acosmicraymeasurementfacilityforatlasmuonchambers
AT boutemeurm acosmicraymeasurementfacilityforatlasmuonchambers
AT brandta acosmicraymeasurementfacilityforatlasmuonchambers
AT dubbertj acosmicraymeasurementfacilityforatlasmuonchambers
AT duckeckg acosmicraymeasurementfacilityforatlasmuonchambers
AT elmsheuserj acosmicraymeasurementfacilityforatlasmuonchambers
AT fiedlerf acosmicraymeasurementfacilityforatlasmuonchambers
AT hertenbergerr acosmicraymeasurementfacilityforatlasmuonchambers
AT kortnero acosmicraymeasurementfacilityforatlasmuonchambers
AT nunnemannt acosmicraymeasurementfacilityforatlasmuonchambers
AT rauscherf acosmicraymeasurementfacilityforatlasmuonchambers
AT schailed acosmicraymeasurementfacilityforatlasmuonchambers
AT schieferdeckerp acosmicraymeasurementfacilityforatlasmuonchambers
AT staudea acosmicraymeasurementfacilityforatlasmuonchambers
AT stillerw acosmicraymeasurementfacilityforatlasmuonchambers
AT strohmerr acosmicraymeasurementfacilityforatlasmuonchambers
AT vertesir acosmicraymeasurementfacilityforatlasmuonchambers
AT biebelo cosmicraymeasurementfacilityforatlasmuonchambers
AT binderm cosmicraymeasurementfacilityforatlasmuonchambers
AT boutemeurm cosmicraymeasurementfacilityforatlasmuonchambers
AT brandta cosmicraymeasurementfacilityforatlasmuonchambers
AT dubbertj cosmicraymeasurementfacilityforatlasmuonchambers
AT duckeckg cosmicraymeasurementfacilityforatlasmuonchambers
AT elmsheuserj cosmicraymeasurementfacilityforatlasmuonchambers
AT fiedlerf cosmicraymeasurementfacilityforatlasmuonchambers
AT hertenbergerr cosmicraymeasurementfacilityforatlasmuonchambers
AT kortnero cosmicraymeasurementfacilityforatlasmuonchambers
AT nunnemannt cosmicraymeasurementfacilityforatlasmuonchambers
AT rauscherf cosmicraymeasurementfacilityforatlasmuonchambers
AT schailed cosmicraymeasurementfacilityforatlasmuonchambers
AT schieferdeckerp cosmicraymeasurementfacilityforatlasmuonchambers
AT staudea cosmicraymeasurementfacilityforatlasmuonchambers
AT stillerw cosmicraymeasurementfacilityforatlasmuonchambers
AT strohmerr cosmicraymeasurementfacilityforatlasmuonchambers
AT vertesir cosmicraymeasurementfacilityforatlasmuonchambers