Cargando…
Intelligent trigger processor for the crystal box
A large solid angle angular modular NaI(Tl) detector with 432 phototubes and 88 trigger scintillators is being used to search simultaneously for three lepton flavor-changing decays of the muon. A beam of up to 10/sup 6/ muons stopping per second with a 6% duty factor would yield up to 1000 triggers...
Autores principales: | , , , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
CERN
1981
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.5170/CERN-1981-007.214 http://cds.cern.ch/record/862901 |
_version_ | 1780907253233090560 |
---|---|
author | Sanders, G H Butler, H S Cooper, M D Hart, G W Hoffman, C M Hogan, G E Hughes, E B Matis, H S Rolfe, J Sandberg, V D Williams, R A Wilson, S Zeman, H |
author_facet | Sanders, G H Butler, H S Cooper, M D Hart, G W Hoffman, C M Hogan, G E Hughes, E B Matis, H S Rolfe, J Sandberg, V D Williams, R A Wilson, S Zeman, H |
author_sort | Sanders, G H |
collection | CERN |
description | A large solid angle angular modular NaI(Tl) detector with 432 phototubes and 88 trigger scintillators is being used to search simultaneously for three lepton flavor-changing decays of the muon. A beam of up to 10/sup 6/ muons stopping per second with a 6% duty factor would yield up to 1000 triggers per second from random triple coincidences. A reduction of the trigger rate to 10 Hz is required from a hardwired primary trigger processor. Further reduction to <1 Hz is achieved by a microprocessor-based secondary trigger processor. The primary trigger hardware imposes voter coincidence logic, stringent timing requirements, and a non-adjacency requirement in the trigger scintillators defined by hardwired circuits. Sophisticated geometric requirements are imposed by a PROM-based matrix logic, and energy and vector-momentum cuts are imposed by a hardwired processor using LSI flash ADC's and digital arithmetic logic. The secondary trigger employs four satellite microprocessors to do a sparse data scan, multiplex the data acquisition channels and apply additional event filtering. (9 refs). |
id | cern-862901 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1981 |
publisher | CERN |
record_format | invenio |
spelling | cern-8629012019-09-30T06:29:59Zdoi:10.5170/CERN-1981-007.214http://cds.cern.ch/record/862901engSanders, G HButler, H SCooper, M DHart, G WHoffman, C MHogan, G EHughes, E BMatis, H SRolfe, JSandberg, V DWilliams, R AWilson, SZeman, HIntelligent trigger processor for the crystal boxNuclear PhysicsA large solid angle angular modular NaI(Tl) detector with 432 phototubes and 88 trigger scintillators is being used to search simultaneously for three lepton flavor-changing decays of the muon. A beam of up to 10/sup 6/ muons stopping per second with a 6% duty factor would yield up to 1000 triggers per second from random triple coincidences. A reduction of the trigger rate to 10 Hz is required from a hardwired primary trigger processor. Further reduction to <1 Hz is achieved by a microprocessor-based secondary trigger processor. The primary trigger hardware imposes voter coincidence logic, stringent timing requirements, and a non-adjacency requirement in the trigger scintillators defined by hardwired circuits. Sophisticated geometric requirements are imposed by a PROM-based matrix logic, and energy and vector-momentum cuts are imposed by a hardwired processor using LSI flash ADC's and digital arithmetic logic. The secondary trigger employs four satellite microprocessors to do a sparse data scan, multiplex the data acquisition channels and apply additional event filtering. (9 refs).CERNoai:cds.cern.ch:8629011981 |
spellingShingle | Nuclear Physics Sanders, G H Butler, H S Cooper, M D Hart, G W Hoffman, C M Hogan, G E Hughes, E B Matis, H S Rolfe, J Sandberg, V D Williams, R A Wilson, S Zeman, H Intelligent trigger processor for the crystal box |
title | Intelligent trigger processor for the crystal box |
title_full | Intelligent trigger processor for the crystal box |
title_fullStr | Intelligent trigger processor for the crystal box |
title_full_unstemmed | Intelligent trigger processor for the crystal box |
title_short | Intelligent trigger processor for the crystal box |
title_sort | intelligent trigger processor for the crystal box |
topic | Nuclear Physics |
url | https://dx.doi.org/10.5170/CERN-1981-007.214 http://cds.cern.ch/record/862901 |
work_keys_str_mv | AT sandersgh intelligenttriggerprocessorforthecrystalbox AT butlerhs intelligenttriggerprocessorforthecrystalbox AT coopermd intelligenttriggerprocessorforthecrystalbox AT hartgw intelligenttriggerprocessorforthecrystalbox AT hoffmancm intelligenttriggerprocessorforthecrystalbox AT hogange intelligenttriggerprocessorforthecrystalbox AT hugheseb intelligenttriggerprocessorforthecrystalbox AT matishs intelligenttriggerprocessorforthecrystalbox AT rolfej intelligenttriggerprocessorforthecrystalbox AT sandbergvd intelligenttriggerprocessorforthecrystalbox AT williamsra intelligenttriggerprocessorforthecrystalbox AT wilsons intelligenttriggerprocessorforthecrystalbox AT zemanh intelligenttriggerprocessorforthecrystalbox |