Cargando…
New deflected-beam gauge for pressures below 10/sup -12/ Torr
A new ionization gauge for measurement of total gas pressures between 10/sup -12/ torr and 10/sup -14/ torr is described. The gauge's main features are a pair of collimating slots below the grid structure, two concentric hemi-spherical deflecting electrodes and a channel electron multiplier whi...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
1975
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1116/1.568464 http://cds.cern.ch/record/873168 |
_version_ | 1780907645010444288 |
---|---|
author | Blechschmidt, Diether |
author_facet | Blechschmidt, Diether |
author_sort | Blechschmidt, Diether |
collection | CERN |
description | A new ionization gauge for measurement of total gas pressures between 10/sup -12/ torr and 10/sup -14/ torr is described. The gauge's main features are a pair of collimating slots below the grid structure, two concentric hemi-spherical deflecting electrodes and a channel electron multiplier which detects low-energy ions passing through the deflector system. The detection of low-energy ions allows discrimination against desorbed ions (which are more energetic), while spurious signals due to X-rays may also be rejected. The channel electron multiplier leads to gauge sensitivities which are much higher than those of ordinary ionization gauges. The gauge has been tested down to 4*10/sup -13/ torr and found to have sensitivities of 1.5*10/sup 17/ and 8*10/sup 16 / counts/s.A.torr for N/sub 2/ and H/sub 2/ respectively. For a channel electron multiplier gain of 10/sup 7/ the gauge sensitivity is thus approximately=10/sup 5//torr. (17 refs). |
id | cern-873168 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1975 |
record_format | invenio |
spelling | cern-8731682019-09-30T06:29:59Zdoi:10.1116/1.568464http://cds.cern.ch/record/873168engBlechschmidt, DietherNew deflected-beam gauge for pressures below 10/sup -12/ TorrDetectors and Experimental TechniquesA new ionization gauge for measurement of total gas pressures between 10/sup -12/ torr and 10/sup -14/ torr is described. The gauge's main features are a pair of collimating slots below the grid structure, two concentric hemi-spherical deflecting electrodes and a channel electron multiplier which detects low-energy ions passing through the deflector system. The detection of low-energy ions allows discrimination against desorbed ions (which are more energetic), while spurious signals due to X-rays may also be rejected. The channel electron multiplier leads to gauge sensitivities which are much higher than those of ordinary ionization gauges. The gauge has been tested down to 4*10/sup -13/ torr and found to have sensitivities of 1.5*10/sup 17/ and 8*10/sup 16 / counts/s.A.torr for N/sub 2/ and H/sub 2/ respectively. For a channel electron multiplier gain of 10/sup 7/ the gauge sensitivity is thus approximately=10/sup 5//torr. (17 refs).oai:cds.cern.ch:8731681975 |
spellingShingle | Detectors and Experimental Techniques Blechschmidt, Diether New deflected-beam gauge for pressures below 10/sup -12/ Torr |
title | New deflected-beam gauge for pressures below 10/sup -12/ Torr |
title_full | New deflected-beam gauge for pressures below 10/sup -12/ Torr |
title_fullStr | New deflected-beam gauge for pressures below 10/sup -12/ Torr |
title_full_unstemmed | New deflected-beam gauge for pressures below 10/sup -12/ Torr |
title_short | New deflected-beam gauge for pressures below 10/sup -12/ Torr |
title_sort | new deflected-beam gauge for pressures below 10/sup -12/ torr |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1116/1.568464 http://cds.cern.ch/record/873168 |
work_keys_str_mv | AT blechschmidtdiether newdeflectedbeamgaugeforpressuresbelow10sup12torr |