Cargando…

Measurements of dose equivalent of mixed radiation outside the Serpukhov proton synchrotron shield

Comparative measurements of radiation doses outside the Serpukhov proton synchrotron shield were made with the component method (CM) and the 'Cerberus' instrument used at the Institute of High Energy Physics (IHEP) and CERN as radiation monitors, and also with the 'Sukhona-2' rec...

Descripción completa

Detalles Bibliográficos
Autores principales: Antipov, A V, Baishev, I S, Golovachik, V T, Khefert, M, Krupnyi, G I, Kustarev, V N, Lebedev, V N
Lenguaje:eng
Publicado: 1979
Materias:
Acceso en línea:https://dx.doi.org/10.1007/BF01207610
http://cds.cern.ch/record/875262
_version_ 1780907799566352384
author Antipov, A V
Baishev, I S
Golovachik, V T
Khefert, M
Krupnyi, G I
Kustarev, V N
Lebedev, V N
author_facet Antipov, A V
Baishev, I S
Golovachik, V T
Khefert, M
Krupnyi, G I
Kustarev, V N
Lebedev, V N
author_sort Antipov, A V
collection CERN
description Comparative measurements of radiation doses outside the Serpukhov proton synchrotron shield were made with the component method (CM) and the 'Cerberus' instrument used at the Institute of High Energy Physics (IHEP) and CERN as radiation monitors, and also with the 'Sukhona-2' recombination dosimeter, a linear energy transfer radiation spectrometer based on a tissue equivalent (TE) proportional counter and a TE ionization chamber, employed at the IHEP for the direct measurements of doses and for calibrating monitoring devices used in radiation fields having an unknown composition and spectrum. (23 refs) .
id cern-875262
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1979
record_format invenio
spelling cern-8752622019-09-30T06:29:59Zdoi:10.1007/BF01207610http://cds.cern.ch/record/875262engAntipov, A VBaishev, I SGolovachik, V TKhefert, MKrupnyi, G IKustarev, V NLebedev, V NMeasurements of dose equivalent of mixed radiation outside the Serpukhov proton synchrotron shieldNuclear PhysicsComparative measurements of radiation doses outside the Serpukhov proton synchrotron shield were made with the component method (CM) and the 'Cerberus' instrument used at the Institute of High Energy Physics (IHEP) and CERN as radiation monitors, and also with the 'Sukhona-2' recombination dosimeter, a linear energy transfer radiation spectrometer based on a tissue equivalent (TE) proportional counter and a TE ionization chamber, employed at the IHEP for the direct measurements of doses and for calibrating monitoring devices used in radiation fields having an unknown composition and spectrum. (23 refs) .oai:cds.cern.ch:8752621979
spellingShingle Nuclear Physics
Antipov, A V
Baishev, I S
Golovachik, V T
Khefert, M
Krupnyi, G I
Kustarev, V N
Lebedev, V N
Measurements of dose equivalent of mixed radiation outside the Serpukhov proton synchrotron shield
title Measurements of dose equivalent of mixed radiation outside the Serpukhov proton synchrotron shield
title_full Measurements of dose equivalent of mixed radiation outside the Serpukhov proton synchrotron shield
title_fullStr Measurements of dose equivalent of mixed radiation outside the Serpukhov proton synchrotron shield
title_full_unstemmed Measurements of dose equivalent of mixed radiation outside the Serpukhov proton synchrotron shield
title_short Measurements of dose equivalent of mixed radiation outside the Serpukhov proton synchrotron shield
title_sort measurements of dose equivalent of mixed radiation outside the serpukhov proton synchrotron shield
topic Nuclear Physics
url https://dx.doi.org/10.1007/BF01207610
http://cds.cern.ch/record/875262
work_keys_str_mv AT antipovav measurementsofdoseequivalentofmixedradiationoutsidetheserpukhovprotonsynchrotronshield
AT baishevis measurementsofdoseequivalentofmixedradiationoutsidetheserpukhovprotonsynchrotronshield
AT golovachikvt measurementsofdoseequivalentofmixedradiationoutsidetheserpukhovprotonsynchrotronshield
AT khefertm measurementsofdoseequivalentofmixedradiationoutsidetheserpukhovprotonsynchrotronshield
AT krupnyigi measurementsofdoseequivalentofmixedradiationoutsidetheserpukhovprotonsynchrotronshield
AT kustarevvn measurementsofdoseequivalentofmixedradiationoutsidetheserpukhovprotonsynchrotronshield
AT lebedevvn measurementsofdoseequivalentofmixedradiationoutsidetheserpukhovprotonsynchrotronshield