Cryogenic design and performance of two quadrupoles used in the CERN hyperon-beam

The two magnets described have a length of 1.35 m and 1.05 m and a cold aperture of 36 mm. They provide focusing powers of 180 T and 130 T with gradients of 156 T/m. They have a fully automatic control and supply, and are supplied with LHe by a 500l dewar. About 9 l/h LHe are necessary when the magn...

Descripción completa

Detalles Bibliográficos
Autores principales: Arendt, F, Katheder, H
Lenguaje:eng
Publicado: 1979
Materias:
Acceso en línea:http://cds.cern.ch/record/875363
Descripción
Sumario:The two magnets described have a length of 1.35 m and 1.05 m and a cold aperture of 36 mm. They provide focusing powers of 180 T and 130 T with gradients of 156 T/m. They have a fully automatic control and supply, and are supplied with LHe by a 500l dewar. About 9 l/h LHe are necessary when the magnets are operated at 445 A. (4 refs).