Cargando…
Photomultipliers output pulse shape
The shape of photomultiplier output pulses has been studied for two operating conditions; single-electron response (SER), and the case when the photomultiplier is associated with a scintillator. An accurate measurement of the SER mean pulse shape has been performed. The comparison of output pulse sh...
Autores principales: | , |
---|---|
Lenguaje: | eng |
Publicado: |
1972
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/0029-554X(72)90489-2 http://cds.cern.ch/record/875567 |
_version_ | 1780907842872541184 |
---|---|
author | Bianchetti, G Righini, B |
author_facet | Bianchetti, G Righini, B |
author_sort | Bianchetti, G |
collection | CERN |
description | The shape of photomultiplier output pulses has been studied for two operating conditions; single-electron response (SER), and the case when the photomultiplier is associated with a scintillator. An accurate measurement of the SER mean pulse shape has been performed. The comparison of output pulse shapes when the PM is placed in a setup that is typical for most nuclear physics experiments showed a dependence of the pulse shape on the pulse amplitude. (3 refs). |
id | cern-875567 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1972 |
record_format | invenio |
spelling | cern-8755672019-09-30T06:29:59Zdoi:10.1016/0029-554X(72)90489-2http://cds.cern.ch/record/875567engBianchetti, GRighini, BPhotomultipliers output pulse shapeNuclear PhysicsThe shape of photomultiplier output pulses has been studied for two operating conditions; single-electron response (SER), and the case when the photomultiplier is associated with a scintillator. An accurate measurement of the SER mean pulse shape has been performed. The comparison of output pulse shapes when the PM is placed in a setup that is typical for most nuclear physics experiments showed a dependence of the pulse shape on the pulse amplitude. (3 refs).oai:cds.cern.ch:8755671972 |
spellingShingle | Nuclear Physics Bianchetti, G Righini, B Photomultipliers output pulse shape |
title | Photomultipliers output pulse shape |
title_full | Photomultipliers output pulse shape |
title_fullStr | Photomultipliers output pulse shape |
title_full_unstemmed | Photomultipliers output pulse shape |
title_short | Photomultipliers output pulse shape |
title_sort | photomultipliers output pulse shape |
topic | Nuclear Physics |
url | https://dx.doi.org/10.1016/0029-554X(72)90489-2 http://cds.cern.ch/record/875567 |
work_keys_str_mv | AT bianchettig photomultipliersoutputpulseshape AT righinib photomultipliersoutputpulseshape |