Cargando…

Variations in the characteristics of the superconducting wire used for the ISR superconducting high-luminosity insertion

A total of 30000 meters of NbTi solid multifilamentary superconductor, I/sub c/ approximately 2500 A at 6 T, was tested. For each stretch of wire received, measurements were made to check if the wire met the specifications. The specification and the measuring set-up are described. Systematic measure...

Descripción completa

Detalles Bibliográficos
Autores principales: Billan, J, Rinn, J, Wolf, R
Lenguaje:eng
Publicado: 1981
Materias:
Acceso en línea:https://dx.doi.org/10.1109/TMAG.1981.1061115
http://cds.cern.ch/record/878300
_version_ 1780907972675764224
author Billan, J
Rinn, J
Wolf, R
author_facet Billan, J
Rinn, J
Wolf, R
author_sort Billan, J
collection CERN
description A total of 30000 meters of NbTi solid multifilamentary superconductor, I/sub c/ approximately 2500 A at 6 T, was tested. For each stretch of wire received, measurements were made to check if the wire met the specifications. The specification and the measuring set-up are described. Systematic measurements of the critical currents, Cu:SC ratio, Ti content and wire size are discussed. A strong variation in the critical current could be correlated to a strong variation in the Ti content. (4 refs).
id cern-878300
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1981
record_format invenio
spelling cern-8783002019-09-30T06:29:59Zdoi:10.1109/TMAG.1981.1061115http://cds.cern.ch/record/878300engBillan, JRinn, JWolf, RVariations in the characteristics of the superconducting wire used for the ISR superconducting high-luminosity insertionNuclear PhysicsA total of 30000 meters of NbTi solid multifilamentary superconductor, I/sub c/ approximately 2500 A at 6 T, was tested. For each stretch of wire received, measurements were made to check if the wire met the specifications. The specification and the measuring set-up are described. Systematic measurements of the critical currents, Cu:SC ratio, Ti content and wire size are discussed. A strong variation in the critical current could be correlated to a strong variation in the Ti content. (4 refs).oai:cds.cern.ch:8783001981
spellingShingle Nuclear Physics
Billan, J
Rinn, J
Wolf, R
Variations in the characteristics of the superconducting wire used for the ISR superconducting high-luminosity insertion
title Variations in the characteristics of the superconducting wire used for the ISR superconducting high-luminosity insertion
title_full Variations in the characteristics of the superconducting wire used for the ISR superconducting high-luminosity insertion
title_fullStr Variations in the characteristics of the superconducting wire used for the ISR superconducting high-luminosity insertion
title_full_unstemmed Variations in the characteristics of the superconducting wire used for the ISR superconducting high-luminosity insertion
title_short Variations in the characteristics of the superconducting wire used for the ISR superconducting high-luminosity insertion
title_sort variations in the characteristics of the superconducting wire used for the isr superconducting high-luminosity insertion
topic Nuclear Physics
url https://dx.doi.org/10.1109/TMAG.1981.1061115
http://cds.cern.ch/record/878300
work_keys_str_mv AT billanj variationsinthecharacteristicsofthesuperconductingwireusedfortheisrsuperconductinghighluminosityinsertion
AT rinnj variationsinthecharacteristicsofthesuperconductingwireusedfortheisrsuperconductinghighluminosityinsertion
AT wolfr variationsinthecharacteristicsofthesuperconductingwireusedfortheisrsuperconductinghighluminosityinsertion