Cargando…

Determination of some parameters for pion radiobiology studies

An experimental investigation of the central axis depth-dose and stopping rate distribution of the SIN biomedical pion beam is reported. The pion stopping rate in a thin disc of tissue-equivalent plastic was determined using a counter telescope. The dose rate at the position of this disc 'targe...

Descripción completa

Detalles Bibliográficos
Autores principales: Nordell, B, Baarli, Johan, Sullivan, A H, Zielczynski, M
Lenguaje:eng
Publicado: 1977
Materias:
Acceso en línea:https://dx.doi.org/10.1088/0031-9155/22/3/007
http://cds.cern.ch/record/878622
_version_ 1780908009628631040
author Nordell, B
Baarli, Johan
Sullivan, A H
Zielczynski, M
author_facet Nordell, B
Baarli, Johan
Sullivan, A H
Zielczynski, M
author_sort Nordell, B
collection CERN
description An experimental investigation of the central axis depth-dose and stopping rate distribution of the SIN biomedical pion beam is reported. The pion stopping rate in a thin disc of tissue-equivalent plastic was determined using a counter telescope. The dose rate at the position of this disc 'target' was measured using a specially designed parallel-plate tissue-equivalent ionization chamber. Both dose rate and pion stopping rate are given as a function of depth for beams of two different momenta spread. The energy deposition required per pion stop to fit the measured dose rate curves was calculated and found to be between 37 and 40 MeV. From the stopping rate measurements the depth-dose distribution of pion interaction dose (star-dose) and the dose due to the pion slowing down were evaluated. (8 refs).
id cern-878622
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 1977
record_format invenio
spelling cern-8786222019-09-30T06:29:59Zdoi:10.1088/0031-9155/22/3/007http://cds.cern.ch/record/878622engNordell, BBaarli, JohanSullivan, A HZielczynski, MDetermination of some parameters for pion radiobiology studiesHealth Physics and Radiation EffectsAn experimental investigation of the central axis depth-dose and stopping rate distribution of the SIN biomedical pion beam is reported. The pion stopping rate in a thin disc of tissue-equivalent plastic was determined using a counter telescope. The dose rate at the position of this disc 'target' was measured using a specially designed parallel-plate tissue-equivalent ionization chamber. Both dose rate and pion stopping rate are given as a function of depth for beams of two different momenta spread. The energy deposition required per pion stop to fit the measured dose rate curves was calculated and found to be between 37 and 40 MeV. From the stopping rate measurements the depth-dose distribution of pion interaction dose (star-dose) and the dose due to the pion slowing down were evaluated. (8 refs).oai:cds.cern.ch:8786221977
spellingShingle Health Physics and Radiation Effects
Nordell, B
Baarli, Johan
Sullivan, A H
Zielczynski, M
Determination of some parameters for pion radiobiology studies
title Determination of some parameters for pion radiobiology studies
title_full Determination of some parameters for pion radiobiology studies
title_fullStr Determination of some parameters for pion radiobiology studies
title_full_unstemmed Determination of some parameters for pion radiobiology studies
title_short Determination of some parameters for pion radiobiology studies
title_sort determination of some parameters for pion radiobiology studies
topic Health Physics and Radiation Effects
url https://dx.doi.org/10.1088/0031-9155/22/3/007
http://cds.cern.ch/record/878622
work_keys_str_mv AT nordellb determinationofsomeparametersforpionradiobiologystudies
AT baarlijohan determinationofsomeparametersforpionradiobiologystudies
AT sullivanah determinationofsomeparametersforpionradiobiologystudies
AT zielczynskim determinationofsomeparametersforpionradiobiologystudies