Cargando…
An ionisation gauge using a channel electron multiplier for pressures below 10$\^{-12}$
Since new techniques to achieve pressures of below 10/sup -12/ Torr have been developed, gauges with an appropriate low pressure limit are required. Channeltrons, with their high gain, seem to be the best means to construct gauges with high sensitivity. In this paper a new ionisation gauge using a c...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
1973
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1116/1.1317069 http://cds.cern.ch/record/880738 |
_version_ | 1780908183872602112 |
---|---|
author | Blechschmidt, Diether |
author_facet | Blechschmidt, Diether |
author_sort | Blechschmidt, Diether |
collection | CERN |
description | Since new techniques to achieve pressures of below 10/sup -12/ Torr have been developed, gauges with an appropriate low pressure limit are required. Channeltrons, with their high gain, seem to be the best means to construct gauges with high sensitivity. In this paper a new ionisation gauge using a channeltron has been described. (15 refs). |
id | cern-880738 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 1973 |
record_format | invenio |
spelling | cern-8807382019-09-30T06:29:59Zdoi:10.1116/1.1317069http://cds.cern.ch/record/880738engBlechschmidt, DietherAn ionisation gauge using a channel electron multiplier for pressures below 10$\^{-12}$Detectors and Experimental TechniquesSince new techniques to achieve pressures of below 10/sup -12/ Torr have been developed, gauges with an appropriate low pressure limit are required. Channeltrons, with their high gain, seem to be the best means to construct gauges with high sensitivity. In this paper a new ionisation gauge using a channeltron has been described. (15 refs).oai:cds.cern.ch:8807381973 |
spellingShingle | Detectors and Experimental Techniques Blechschmidt, Diether An ionisation gauge using a channel electron multiplier for pressures below 10$\^{-12}$ |
title | An ionisation gauge using a channel electron multiplier for pressures below 10$\^{-12}$ |
title_full | An ionisation gauge using a channel electron multiplier for pressures below 10$\^{-12}$ |
title_fullStr | An ionisation gauge using a channel electron multiplier for pressures below 10$\^{-12}$ |
title_full_unstemmed | An ionisation gauge using a channel electron multiplier for pressures below 10$\^{-12}$ |
title_short | An ionisation gauge using a channel electron multiplier for pressures below 10$\^{-12}$ |
title_sort | ionisation gauge using a channel electron multiplier for pressures below 10$\^{-12}$ |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1116/1.1317069 http://cds.cern.ch/record/880738 |
work_keys_str_mv | AT blechschmidtdiether anionisationgaugeusingachannelelectronmultiplierforpressuresbelow1012 AT blechschmidtdiether ionisationgaugeusingachannelelectronmultiplierforpressuresbelow1012 |