A two-step high voltage pulse generator

A new extraction system for the transfer of protons between synchrotrons at CERN has necessitated the building of special high voltage pulse generators delivering two-step pulses. The maximum pulse power of each step is 100 MW in 15 ohm and is independently variable. The pulse length of each step, a...

Descripción completa

Detalles Bibliográficos
Autores principales: Fiander, D C, Grier, D, Metzmacher, K D, Pearce, P
Lenguaje:eng
Publicado: 1980
Materias:
Acceso en línea:http://cds.cern.ch/record/881855
Descripción
Sumario:A new extraction system for the transfer of protons between synchrotrons at CERN has necessitated the building of special high voltage pulse generators delivering two-step pulses. The maximum pulse power of each step is 100 MW in 15 ohm and is independently variable. The pulse length of each step, also independently variable, is 1.6+or-0.5 mu s. Pulse rise and fall times are about 30 ns. (2 refs).