Cargando…

Beam based Alignment of the LHC Transfer Line Collimators

At LHC injection energy the aperture available in the transfer lines and in the LHC is small and the intensities of the injected beams are an order of magnitude above the damage level. The setting of protection elements such as the transfer line collimators is therefore very critical; mechanical and...

Descripción completa

Detalles Bibliográficos
Autores principales: Kain, Verena, Burkhardt, Helmut, Goddard, Brennan, Redaelli, Stefano
Lenguaje:eng
Publicado: 2005
Materias:
Acceso en línea:http://cds.cern.ch/record/882893
_version_ 1780908272299016192
author Kain, Verena
Burkhardt, Helmut
Goddard, Brennan
Redaelli, Stefano
author_facet Kain, Verena
Burkhardt, Helmut
Goddard, Brennan
Redaelli, Stefano
author_sort Kain, Verena
collection CERN
description At LHC injection energy the aperture available in the transfer lines and in the LHC is small and the intensities of the injected beams are an order of magnitude above the damage level. The setting of protection elements such as the transfer line collimators is therefore very critical; mechanical and optical tolerances must be taken into account to define the nominal setting. Being able to measure and control the collinearity of the collimator jaws with the beam relaxes the requirement on the settings considerably. A method to measure angular misalignment of the collimator jaws in the transfer line based on a transmission measurement is discussed. Simulations have been made and a test of principle has been carried out during the 2004 commissioning of the transfer line TI 8.
id cern-882893
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2005
record_format invenio
spelling cern-8828932023-05-31T13:23:07Zhttp://cds.cern.ch/record/882893engKain, VerenaBurkhardt, HelmutGoddard, BrennanRedaelli, StefanoBeam based Alignment of the LHC Transfer Line CollimatorsAccelerators and Storage RingsAt LHC injection energy the aperture available in the transfer lines and in the LHC is small and the intensities of the injected beams are an order of magnitude above the damage level. The setting of protection elements such as the transfer line collimators is therefore very critical; mechanical and optical tolerances must be taken into account to define the nominal setting. Being able to measure and control the collinearity of the collimator jaws with the beam relaxes the requirement on the settings considerably. A method to measure angular misalignment of the collimator jaws in the transfer line based on a transmission measurement is discussed. Simulations have been made and a test of principle has been carried out during the 2004 commissioning of the transfer line TI 8.LHC-Project-Report-852CERN-LHC-Project-Report-852oai:cds.cern.ch:8828932005-08-01
spellingShingle Accelerators and Storage Rings
Kain, Verena
Burkhardt, Helmut
Goddard, Brennan
Redaelli, Stefano
Beam based Alignment of the LHC Transfer Line Collimators
title Beam based Alignment of the LHC Transfer Line Collimators
title_full Beam based Alignment of the LHC Transfer Line Collimators
title_fullStr Beam based Alignment of the LHC Transfer Line Collimators
title_full_unstemmed Beam based Alignment of the LHC Transfer Line Collimators
title_short Beam based Alignment of the LHC Transfer Line Collimators
title_sort beam based alignment of the lhc transfer line collimators
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/882893
work_keys_str_mv AT kainverena beambasedalignmentofthelhctransferlinecollimators
AT burkhardthelmut beambasedalignmentofthelhctransferlinecollimators
AT goddardbrennan beambasedalignmentofthelhctransferlinecollimators
AT redaellistefano beambasedalignmentofthelhctransferlinecollimators