Cargando…
ATLAS Inner Detector Performance with the Rome-Initial Layout
The performance of the ATLAS Inner Detector with the Rome-Initial Layout has been studied for single muons using the Geant4 framework and the iPatRec software package. The results have been assessed and compared with those derived within the Geant3 framework for the DC1 layout. No significant change...
Autores principales: | , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2005
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/889551 |
_version_ | 1780908393227091968 |
---|---|
author | Poppleton, A Benekos, N Clifft, R Dallison, S Gorfine, G |
author_facet | Poppleton, A Benekos, N Clifft, R Dallison, S Gorfine, G |
author_sort | Poppleton, A |
collection | CERN |
description | The performance of the ATLAS Inner Detector with the Rome-Initial Layout has been studied for single muons using the Geant4 framework and the iPatRec software package. The results have been assessed and compared with those derived within the Geant3 framework for the DC1 layout. No significant change in performance as measured by transverse impact parameter or pT resolution is visible but a small decrease in longitudinal impact parameter resolution is observed, attributed to increased pixel size. Systematic shifts away from the truth, in the mean reconstructed track momentum were found during the studies. Some of these deviations are shown. An explanation for the problem has recently been found. The solution is discussed and some corrected results are shown. |
id | cern-889551 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2005 |
record_format | invenio |
spelling | cern-8895512019-09-30T06:29:59Zhttp://cds.cern.ch/record/889551engPoppleton, ABenekos, NClifft, RDallison, SGorfine, GATLAS Inner Detector Performance with the Rome-Initial LayoutDetectors and Experimental TechniquesThe performance of the ATLAS Inner Detector with the Rome-Initial Layout has been studied for single muons using the Geant4 framework and the iPatRec software package. The results have been assessed and compared with those derived within the Geant3 framework for the DC1 layout. No significant change in performance as measured by transverse impact parameter or pT resolution is visible but a small decrease in longitudinal impact parameter resolution is observed, attributed to increased pixel size. Systematic shifts away from the truth, in the mean reconstructed track momentum were found during the studies. Some of these deviations are shown. An explanation for the problem has recently been found. The solution is discussed and some corrected results are shown.ATL-INDET-PUB-2007-008ATL-COM-INDET-2005-008oai:cds.cern.ch:8895512005-10-04 |
spellingShingle | Detectors and Experimental Techniques Poppleton, A Benekos, N Clifft, R Dallison, S Gorfine, G ATLAS Inner Detector Performance with the Rome-Initial Layout |
title | ATLAS Inner Detector Performance with the Rome-Initial Layout |
title_full | ATLAS Inner Detector Performance with the Rome-Initial Layout |
title_fullStr | ATLAS Inner Detector Performance with the Rome-Initial Layout |
title_full_unstemmed | ATLAS Inner Detector Performance with the Rome-Initial Layout |
title_short | ATLAS Inner Detector Performance with the Rome-Initial Layout |
title_sort | atlas inner detector performance with the rome-initial layout |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/889551 |
work_keys_str_mv | AT poppletona atlasinnerdetectorperformancewiththeromeinitiallayout AT benekosn atlasinnerdetectorperformancewiththeromeinitiallayout AT clifftr atlasinnerdetectorperformancewiththeromeinitiallayout AT dallisons atlasinnerdetectorperformancewiththeromeinitiallayout AT gorfineg atlasinnerdetectorperformancewiththeromeinitiallayout |