Cargando…
Time resolved energy measurement at CTF3
The high charge (>6μC) electron beams produced in the CLIC Test Facility 3 (CTF3) is accelerated in fully loaded cavities. Leading to a strong transient effect, the time evolution of the beam energy and its energy spread must be measured with at least 50MHz bandwidth. Three different detectors ha...
Autores principales: | , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2005
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/895151 |
_version_ | 1780908590729527296 |
---|---|
author | Braun, H Bravin, E Chritin, N Corsini, R Dutriat, C Lefèvre, T Tecker, F A Welsch, C |
author_facet | Braun, H Bravin, E Chritin, N Corsini, R Dutriat, C Lefèvre, T Tecker, F A Welsch, C |
author_sort | Braun, H |
collection | CERN |
description | The high charge (>6μC) electron beams produced in the CLIC Test Facility 3 (CTF3) is accelerated in fully loaded cavities. Leading to a strong transient effect, the time evolution of the beam energy and its energy spread must be measured with at least 50MHz bandwidth. Three different detectors have been installed and tested so far on the three existing spectrometer lines of the machine: a secondary emission wire grid, a segmented beam dump and a segmented photomultiplier tube observing OTR emissions. This contribution describes the three devices and gives a comparison of the relative performances. |
id | cern-895151 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2005 |
record_format | invenio |
spelling | cern-8951512023-07-20T15:04:43Zhttp://cds.cern.ch/record/895151engBraun, HBravin, EChritin, NCorsini, RDutriat, CLefèvre, TTecker, F AWelsch, CTime resolved energy measurement at CTF3Accelerators and Storage RingsThe high charge (>6μC) electron beams produced in the CLIC Test Facility 3 (CTF3) is accelerated in fully loaded cavities. Leading to a strong transient effect, the time evolution of the beam energy and its energy spread must be measured with at least 50MHz bandwidth. Three different detectors have been installed and tested so far on the three existing spectrometer lines of the machine: a secondary emission wire grid, a segmented beam dump and a segmented photomultiplier tube observing OTR emissions. This contribution describes the three devices and gives a comparison of the relative performances.CERN-AB-2005-068CLIC-Note-661oai:cds.cern.ch:8951512005-04-01 |
spellingShingle | Accelerators and Storage Rings Braun, H Bravin, E Chritin, N Corsini, R Dutriat, C Lefèvre, T Tecker, F A Welsch, C Time resolved energy measurement at CTF3 |
title | Time resolved energy measurement at CTF3 |
title_full | Time resolved energy measurement at CTF3 |
title_fullStr | Time resolved energy measurement at CTF3 |
title_full_unstemmed | Time resolved energy measurement at CTF3 |
title_short | Time resolved energy measurement at CTF3 |
title_sort | time resolved energy measurement at ctf3 |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/895151 |
work_keys_str_mv | AT braunh timeresolvedenergymeasurementatctf3 AT bravine timeresolvedenergymeasurementatctf3 AT chritinn timeresolvedenergymeasurementatctf3 AT corsinir timeresolvedenergymeasurementatctf3 AT dutriatc timeresolvedenergymeasurementatctf3 AT lefevret timeresolvedenergymeasurementatctf3 AT teckerfa timeresolvedenergymeasurementatctf3 AT welschc timeresolvedenergymeasurementatctf3 |