Cargando…

Time resolved energy measurement at CTF3

The high charge (>6μC) electron beams produced in the CLIC Test Facility 3 (CTF3) is accelerated in fully loaded cavities. Leading to a strong transient effect, the time evolution of the beam energy and its energy spread must be measured with at least 50MHz bandwidth. Three different detectors ha...

Descripción completa

Detalles Bibliográficos
Autores principales: Braun, H, Bravin, E, Chritin, N, Corsini, R, Dutriat, C, Lefèvre, T, Tecker, F A, Welsch, C
Lenguaje:eng
Publicado: 2005
Materias:
Acceso en línea:http://cds.cern.ch/record/895151
_version_ 1780908590729527296
author Braun, H
Bravin, E
Chritin, N
Corsini, R
Dutriat, C
Lefèvre, T
Tecker, F A
Welsch, C
author_facet Braun, H
Bravin, E
Chritin, N
Corsini, R
Dutriat, C
Lefèvre, T
Tecker, F A
Welsch, C
author_sort Braun, H
collection CERN
description The high charge (>6μC) electron beams produced in the CLIC Test Facility 3 (CTF3) is accelerated in fully loaded cavities. Leading to a strong transient effect, the time evolution of the beam energy and its energy spread must be measured with at least 50MHz bandwidth. Three different detectors have been installed and tested so far on the three existing spectrometer lines of the machine: a secondary emission wire grid, a segmented beam dump and a segmented photomultiplier tube observing OTR emissions. This contribution describes the three devices and gives a comparison of the relative performances.
id cern-895151
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2005
record_format invenio
spelling cern-8951512023-07-20T15:04:43Zhttp://cds.cern.ch/record/895151engBraun, HBravin, EChritin, NCorsini, RDutriat, CLefèvre, TTecker, F AWelsch, CTime resolved energy measurement at CTF3Accelerators and Storage RingsThe high charge (>6μC) electron beams produced in the CLIC Test Facility 3 (CTF3) is accelerated in fully loaded cavities. Leading to a strong transient effect, the time evolution of the beam energy and its energy spread must be measured with at least 50MHz bandwidth. Three different detectors have been installed and tested so far on the three existing spectrometer lines of the machine: a secondary emission wire grid, a segmented beam dump and a segmented photomultiplier tube observing OTR emissions. This contribution describes the three devices and gives a comparison of the relative performances.CERN-AB-2005-068CLIC-Note-661oai:cds.cern.ch:8951512005-04-01
spellingShingle Accelerators and Storage Rings
Braun, H
Bravin, E
Chritin, N
Corsini, R
Dutriat, C
Lefèvre, T
Tecker, F A
Welsch, C
Time resolved energy measurement at CTF3
title Time resolved energy measurement at CTF3
title_full Time resolved energy measurement at CTF3
title_fullStr Time resolved energy measurement at CTF3
title_full_unstemmed Time resolved energy measurement at CTF3
title_short Time resolved energy measurement at CTF3
title_sort time resolved energy measurement at ctf3
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/895151
work_keys_str_mv AT braunh timeresolvedenergymeasurementatctf3
AT bravine timeresolvedenergymeasurementatctf3
AT chritinn timeresolvedenergymeasurementatctf3
AT corsinir timeresolvedenergymeasurementatctf3
AT dutriatc timeresolvedenergymeasurementatctf3
AT lefevret timeresolvedenergymeasurementatctf3
AT teckerfa timeresolvedenergymeasurementatctf3
AT welschc timeresolvedenergymeasurementatctf3