Cargando…

Accuracy of the SPS transverse emittance monitors

A campaign of studies and measurements has been carried out with the aim of establishing the SPS transverse profile monitors resolution, reproducibility and accuracy. The studies regarded systematic dependencies of the SPS Wire Scanner (WS) monitors on the operation setups and on the beam parameters...

Descripción completa

Detalles Bibliográficos
Autores principales: Dehning, B, Fischer, C, Koopman, J, Roncarolo, F
Lenguaje:eng
Publicado: 2005
Materias:
Acceso en línea:http://cds.cern.ch/record/895164
_version_ 1780908593523982336
author Dehning, B
Fischer, C
Koopman, J
Roncarolo, F
author_facet Dehning, B
Fischer, C
Koopman, J
Roncarolo, F
author_sort Dehning, B
collection CERN
description A campaign of studies and measurements has been carried out with the aim of establishing the SPS transverse profile monitors resolution, reproducibility and accuracy. The studies regarded systematic dependencies of the SPS Wire Scanner (WS) monitors on the operation setups and on the beam parameters, like beam intensity, bunch spacing and beam size. The emittance increase due to multiple Coulomb scattering during the linear WS operation has been measured and compared with the theoretical model prediction. Numerical simulations estimate the errors introduced by the limited resolution of the imaging systems and by excessive electronic noise of the detectors. The experimental measurements have been carried out with a wide range of beams, from the low intensity pilot bunch to the LHC nominal beam. At first the different SPS WS are compared during simultaneous measurements. The SPS IPM vertical profiles have been compared to the WS while tracking the beam emittance from 26 to 450 GeV. The IPM resolution improvements from 2003 to 2004 are pointed out.
id cern-895164
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2005
record_format invenio
spelling cern-8951642022-08-17T13:36:25Zhttp://cds.cern.ch/record/895164engDehning, BFischer, CKoopman, JRoncarolo, FAccuracy of the SPS transverse emittance monitorsAccelerators and Storage RingsA campaign of studies and measurements has been carried out with the aim of establishing the SPS transverse profile monitors resolution, reproducibility and accuracy. The studies regarded systematic dependencies of the SPS Wire Scanner (WS) monitors on the operation setups and on the beam parameters, like beam intensity, bunch spacing and beam size. The emittance increase due to multiple Coulomb scattering during the linear WS operation has been measured and compared with the theoretical model prediction. Numerical simulations estimate the errors introduced by the limited resolution of the imaging systems and by excessive electronic noise of the detectors. The experimental measurements have been carried out with a wide range of beams, from the low intensity pilot bunch to the LHC nominal beam. At first the different SPS WS are compared during simultaneous measurements. The SPS IPM vertical profiles have been compared to the WS while tracking the beam emittance from 26 to 450 GeV. The IPM resolution improvements from 2003 to 2004 are pointed out.CERN-AB-2005-081oai:cds.cern.ch:8951642005-04-01
spellingShingle Accelerators and Storage Rings
Dehning, B
Fischer, C
Koopman, J
Roncarolo, F
Accuracy of the SPS transverse emittance monitors
title Accuracy of the SPS transverse emittance monitors
title_full Accuracy of the SPS transverse emittance monitors
title_fullStr Accuracy of the SPS transverse emittance monitors
title_full_unstemmed Accuracy of the SPS transverse emittance monitors
title_short Accuracy of the SPS transverse emittance monitors
title_sort accuracy of the sps transverse emittance monitors
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/895164
work_keys_str_mv AT dehningb accuracyofthespstransverseemittancemonitors
AT fischerc accuracyofthespstransverseemittancemonitors
AT koopmanj accuracyofthespstransverseemittancemonitors
AT roncarolof accuracyofthespstransverseemittancemonitors