Cargando…
Dosimetry for Crystals Irradiation
Before shipment to CMS, all PbWO4 crystals produced in China are irradiated there with 60 Co , in order to insure that the induced absorption coefficient is within specifications. Acceptance tests at CERNand at ENEA also include irradiation with gamma rays from 60 Co sources. There were initially di...
Autores principales: | , |
---|---|
Lenguaje: | eng |
Publicado: |
2005
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/896898 |
_version_ | 1780908623924297728 |
---|---|
author | Lecomte, Pierre Yuan, Hui |
author_facet | Lecomte, Pierre Yuan, Hui |
author_sort | Lecomte, Pierre |
collection | CERN |
description | Before shipment to CMS, all PbWO4 crystals produced in China are irradiated there with 60 Co , in order to insure that the induced absorption coefficient is within specifications. Acceptance tests at CERNand at ENEA also include irradiation with gamma rays from 60 Co sources. There were initially discrepancies in quoted doses and doserates as well as in induced absorption coefficients. The present work resolves the discrepancies in irradiation measurements and defines common dosimetry methods for consistency checks between irradiation facilities. |
id | cern-896898 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2005 |
record_format | invenio |
spelling | cern-8968982019-09-30T06:29:59Zhttp://cds.cern.ch/record/896898engLecomte, PierreYuan, HuiDosimetry for Crystals IrradiationDetectors and Experimental TechniquesBefore shipment to CMS, all PbWO4 crystals produced in China are irradiated there with 60 Co , in order to insure that the induced absorption coefficient is within specifications. Acceptance tests at CERNand at ENEA also include irradiation with gamma rays from 60 Co sources. There were initially discrepancies in quoted doses and doserates as well as in induced absorption coefficients. The present work resolves the discrepancies in irradiation measurements and defines common dosimetry methods for consistency checks between irradiation facilities.CMS-NOTE-2005-017oai:cds.cern.ch:8968982005-07-22 |
spellingShingle | Detectors and Experimental Techniques Lecomte, Pierre Yuan, Hui Dosimetry for Crystals Irradiation |
title | Dosimetry for Crystals Irradiation |
title_full | Dosimetry for Crystals Irradiation |
title_fullStr | Dosimetry for Crystals Irradiation |
title_full_unstemmed | Dosimetry for Crystals Irradiation |
title_short | Dosimetry for Crystals Irradiation |
title_sort | dosimetry for crystals irradiation |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/896898 |
work_keys_str_mv | AT lecomtepierre dosimetryforcrystalsirradiation AT yuanhui dosimetryforcrystalsirradiation |