Cargando…

X-ray-sensitive hybrid photon detectors with Be-windows

A 0.3-mm thin YAlO/sub 3/(Ce) scintillating crystal plate of 22 mm diameter was mounted inside an electrostatic-focussed hybrid photomultiplier tube (HPMT). The photocathode was evaporated directly on this scintillating plate opposite to the HPMT-anode. The HPMT was vacuum-sealed with a 1-mm thick B...

Descripción completa

Detalles Bibliográficos
Autores principales: D'Ambrosio, Carmelo, De Notaristefani, Francesco, Leutz, Heinrich, Puertolas, D, Rosso, Ettore
Lenguaje:eng
Publicado: 2005
Materias:
Acceso en línea:https://dx.doi.org/10.1109/TNS.2005.850489
http://cds.cern.ch/record/912974
_version_ 1780908933167185920
author D'Ambrosio, Carmelo
De Notaristefani, Francesco
Leutz, Heinrich
Puertolas, D
Rosso, Ettore
author_facet D'Ambrosio, Carmelo
De Notaristefani, Francesco
Leutz, Heinrich
Puertolas, D
Rosso, Ettore
author_sort D'Ambrosio, Carmelo
collection CERN
description A 0.3-mm thin YAlO/sub 3/(Ce) scintillating crystal plate of 22 mm diameter was mounted inside an electrostatic-focussed hybrid photomultiplier tube (HPMT). The photocathode was evaporated directly on this scintillating plate opposite to the HPMT-anode. The HPMT was vacuum-sealed with a 1-mm thick Be radiation entrance window. Photoelectron numbers at their peak energies of photoabsorption and energy resolutions were measured between 3.69 and 59.6 keV. The average number of photoelectrons produced per keV radiation energy was determined to be 4.457 phel/keV and the energy resolution at 59.6 keV was 17%. Introducing in the same way such a thin YAlO/sub 3/(Ce) plate inside an imaging silicon pixel array (ISPA) tube would improve its spatial resolution, since it depends on the thickness of the X- ray detector.
id cern-912974
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2005
record_format invenio
spelling cern-9129742019-09-30T06:29:59Zdoi:10.1109/TNS.2005.850489http://cds.cern.ch/record/912974engD'Ambrosio, CarmeloDe Notaristefani, FrancescoLeutz, HeinrichPuertolas, DRosso, EttoreX-ray-sensitive hybrid photon detectors with Be-windowsDetectors and Experimental TechniquesA 0.3-mm thin YAlO/sub 3/(Ce) scintillating crystal plate of 22 mm diameter was mounted inside an electrostatic-focussed hybrid photomultiplier tube (HPMT). The photocathode was evaporated directly on this scintillating plate opposite to the HPMT-anode. The HPMT was vacuum-sealed with a 1-mm thick Be radiation entrance window. Photoelectron numbers at their peak energies of photoabsorption and energy resolutions were measured between 3.69 and 59.6 keV. The average number of photoelectrons produced per keV radiation energy was determined to be 4.457 phel/keV and the energy resolution at 59.6 keV was 17%. Introducing in the same way such a thin YAlO/sub 3/(Ce) plate inside an imaging silicon pixel array (ISPA) tube would improve its spatial resolution, since it depends on the thickness of the X- ray detector.oai:cds.cern.ch:9129742005
spellingShingle Detectors and Experimental Techniques
D'Ambrosio, Carmelo
De Notaristefani, Francesco
Leutz, Heinrich
Puertolas, D
Rosso, Ettore
X-ray-sensitive hybrid photon detectors with Be-windows
title X-ray-sensitive hybrid photon detectors with Be-windows
title_full X-ray-sensitive hybrid photon detectors with Be-windows
title_fullStr X-ray-sensitive hybrid photon detectors with Be-windows
title_full_unstemmed X-ray-sensitive hybrid photon detectors with Be-windows
title_short X-ray-sensitive hybrid photon detectors with Be-windows
title_sort x-ray-sensitive hybrid photon detectors with be-windows
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1109/TNS.2005.850489
http://cds.cern.ch/record/912974
work_keys_str_mv AT dambrosiocarmelo xraysensitivehybridphotondetectorswithbewindows
AT denotaristefanifrancesco xraysensitivehybridphotondetectorswithbewindows
AT leutzheinrich xraysensitivehybridphotondetectorswithbewindows
AT puertolasd xraysensitivehybridphotondetectorswithbewindows
AT rossoettore xraysensitivehybridphotondetectorswithbewindows