Cargando…

The successful operation of hole-type gaseous detectors at cryogenic temperatures

We have demonstrated that hole-type gaseous detectors, gas electron multipliers and capillary plates (CPs) can operate at temperatures down to 77 K. For example, a single CP can operate at gains above 10 /sup 3/ in the entire temperature interval between 77 and 300 K. The same CP combined with CsI p...

Descripción completa

Detalles Bibliográficos
Autores principales: Periale, Luciano, Francke, Tom, Iacobaeus, C, Lund-Jensen, Bengt, Pavlopoulos, P, Peskov, Vladimir, Picchi, Pio, Pietropaolo, F, Tokanai, F
Lenguaje:eng
Publicado: 2005
Materias:
Acceso en línea:https://dx.doi.org/10.1109/TNS.2005.852632
http://cds.cern.ch/record/913886
_version_ 1780908963901997056
author Periale, Luciano
Francke, Tom
Iacobaeus, C
Lund-Jensen, Bengt
Pavlopoulos, P
Peskov, Vladimir
Picchi, Pio
Pietropaolo, F
Tokanai, F
author_facet Periale, Luciano
Francke, Tom
Iacobaeus, C
Lund-Jensen, Bengt
Pavlopoulos, P
Peskov, Vladimir
Picchi, Pio
Pietropaolo, F
Tokanai, F
author_sort Periale, Luciano
collection CERN
description We have demonstrated that hole-type gaseous detectors, gas electron multipliers and capillary plates (CPs) can operate at temperatures down to 77 K. For example, a single CP can operate at gains above 10 /sup 3/ in the entire temperature interval between 77 and 300 K. The same CP combined with CsI photocathodes operates perfectly well at gains of 100-1000, depending on the gas mixture. The obtained results open new fields of applications for CPs as detectors of ultraviolet light and charged particles at cryogenic temperatures: liquid noble gas time-projection chambers, detectors for weakly interacting massive particles or liquid Xe scintillating calorimeters, and cryogenic positron-emission tomography.
id cern-913886
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2005
record_format invenio
spelling cern-9138862019-09-30T06:29:59Zdoi:10.1109/TNS.2005.852632http://cds.cern.ch/record/913886engPeriale, LucianoFrancke, TomIacobaeus, CLund-Jensen, BengtPavlopoulos, PPeskov, VladimirPicchi, PioPietropaolo, FTokanai, FThe successful operation of hole-type gaseous detectors at cryogenic temperaturesDetectors and Experimental TechniquesWe have demonstrated that hole-type gaseous detectors, gas electron multipliers and capillary plates (CPs) can operate at temperatures down to 77 K. For example, a single CP can operate at gains above 10 /sup 3/ in the entire temperature interval between 77 and 300 K. The same CP combined with CsI photocathodes operates perfectly well at gains of 100-1000, depending on the gas mixture. The obtained results open new fields of applications for CPs as detectors of ultraviolet light and charged particles at cryogenic temperatures: liquid noble gas time-projection chambers, detectors for weakly interacting massive particles or liquid Xe scintillating calorimeters, and cryogenic positron-emission tomography.oai:cds.cern.ch:9138862005
spellingShingle Detectors and Experimental Techniques
Periale, Luciano
Francke, Tom
Iacobaeus, C
Lund-Jensen, Bengt
Pavlopoulos, P
Peskov, Vladimir
Picchi, Pio
Pietropaolo, F
Tokanai, F
The successful operation of hole-type gaseous detectors at cryogenic temperatures
title The successful operation of hole-type gaseous detectors at cryogenic temperatures
title_full The successful operation of hole-type gaseous detectors at cryogenic temperatures
title_fullStr The successful operation of hole-type gaseous detectors at cryogenic temperatures
title_full_unstemmed The successful operation of hole-type gaseous detectors at cryogenic temperatures
title_short The successful operation of hole-type gaseous detectors at cryogenic temperatures
title_sort successful operation of hole-type gaseous detectors at cryogenic temperatures
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1109/TNS.2005.852632
http://cds.cern.ch/record/913886
work_keys_str_mv AT perialeluciano thesuccessfuloperationofholetypegaseousdetectorsatcryogenictemperatures
AT francketom thesuccessfuloperationofholetypegaseousdetectorsatcryogenictemperatures
AT iacobaeusc thesuccessfuloperationofholetypegaseousdetectorsatcryogenictemperatures
AT lundjensenbengt thesuccessfuloperationofholetypegaseousdetectorsatcryogenictemperatures
AT pavlopoulosp thesuccessfuloperationofholetypegaseousdetectorsatcryogenictemperatures
AT peskovvladimir thesuccessfuloperationofholetypegaseousdetectorsatcryogenictemperatures
AT picchipio thesuccessfuloperationofholetypegaseousdetectorsatcryogenictemperatures
AT pietropaolof thesuccessfuloperationofholetypegaseousdetectorsatcryogenictemperatures
AT tokanaif thesuccessfuloperationofholetypegaseousdetectorsatcryogenictemperatures
AT perialeluciano successfuloperationofholetypegaseousdetectorsatcryogenictemperatures
AT francketom successfuloperationofholetypegaseousdetectorsatcryogenictemperatures
AT iacobaeusc successfuloperationofholetypegaseousdetectorsatcryogenictemperatures
AT lundjensenbengt successfuloperationofholetypegaseousdetectorsatcryogenictemperatures
AT pavlopoulosp successfuloperationofholetypegaseousdetectorsatcryogenictemperatures
AT peskovvladimir successfuloperationofholetypegaseousdetectorsatcryogenictemperatures
AT picchipio successfuloperationofholetypegaseousdetectorsatcryogenictemperatures
AT pietropaolof successfuloperationofholetypegaseousdetectorsatcryogenictemperatures
AT tokanaif successfuloperationofholetypegaseousdetectorsatcryogenictemperatures