Cargando…
The successful operation of hole-type gaseous detectors at cryogenic temperatures
We have demonstrated that hole-type gaseous detectors, gas electron multipliers and capillary plates (CPs) can operate at temperatures down to 77 K. For example, a single CP can operate at gains above 10 /sup 3/ in the entire temperature interval between 77 and 300 K. The same CP combined with CsI p...
Autores principales: | , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2005
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1109/TNS.2005.852632 http://cds.cern.ch/record/913886 |
_version_ | 1780908963901997056 |
---|---|
author | Periale, Luciano Francke, Tom Iacobaeus, C Lund-Jensen, Bengt Pavlopoulos, P Peskov, Vladimir Picchi, Pio Pietropaolo, F Tokanai, F |
author_facet | Periale, Luciano Francke, Tom Iacobaeus, C Lund-Jensen, Bengt Pavlopoulos, P Peskov, Vladimir Picchi, Pio Pietropaolo, F Tokanai, F |
author_sort | Periale, Luciano |
collection | CERN |
description | We have demonstrated that hole-type gaseous detectors, gas electron multipliers and capillary plates (CPs) can operate at temperatures down to 77 K. For example, a single CP can operate at gains above 10 /sup 3/ in the entire temperature interval between 77 and 300 K. The same CP combined with CsI photocathodes operates perfectly well at gains of 100-1000, depending on the gas mixture. The obtained results open new fields of applications for CPs as detectors of ultraviolet light and charged particles at cryogenic temperatures: liquid noble gas time-projection chambers, detectors for weakly interacting massive particles or liquid Xe scintillating calorimeters, and cryogenic positron-emission tomography. |
id | cern-913886 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2005 |
record_format | invenio |
spelling | cern-9138862019-09-30T06:29:59Zdoi:10.1109/TNS.2005.852632http://cds.cern.ch/record/913886engPeriale, LucianoFrancke, TomIacobaeus, CLund-Jensen, BengtPavlopoulos, PPeskov, VladimirPicchi, PioPietropaolo, FTokanai, FThe successful operation of hole-type gaseous detectors at cryogenic temperaturesDetectors and Experimental TechniquesWe have demonstrated that hole-type gaseous detectors, gas electron multipliers and capillary plates (CPs) can operate at temperatures down to 77 K. For example, a single CP can operate at gains above 10 /sup 3/ in the entire temperature interval between 77 and 300 K. The same CP combined with CsI photocathodes operates perfectly well at gains of 100-1000, depending on the gas mixture. The obtained results open new fields of applications for CPs as detectors of ultraviolet light and charged particles at cryogenic temperatures: liquid noble gas time-projection chambers, detectors for weakly interacting massive particles or liquid Xe scintillating calorimeters, and cryogenic positron-emission tomography.oai:cds.cern.ch:9138862005 |
spellingShingle | Detectors and Experimental Techniques Periale, Luciano Francke, Tom Iacobaeus, C Lund-Jensen, Bengt Pavlopoulos, P Peskov, Vladimir Picchi, Pio Pietropaolo, F Tokanai, F The successful operation of hole-type gaseous detectors at cryogenic temperatures |
title | The successful operation of hole-type gaseous detectors at cryogenic temperatures |
title_full | The successful operation of hole-type gaseous detectors at cryogenic temperatures |
title_fullStr | The successful operation of hole-type gaseous detectors at cryogenic temperatures |
title_full_unstemmed | The successful operation of hole-type gaseous detectors at cryogenic temperatures |
title_short | The successful operation of hole-type gaseous detectors at cryogenic temperatures |
title_sort | successful operation of hole-type gaseous detectors at cryogenic temperatures |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1109/TNS.2005.852632 http://cds.cern.ch/record/913886 |
work_keys_str_mv | AT perialeluciano thesuccessfuloperationofholetypegaseousdetectorsatcryogenictemperatures AT francketom thesuccessfuloperationofholetypegaseousdetectorsatcryogenictemperatures AT iacobaeusc thesuccessfuloperationofholetypegaseousdetectorsatcryogenictemperatures AT lundjensenbengt thesuccessfuloperationofholetypegaseousdetectorsatcryogenictemperatures AT pavlopoulosp thesuccessfuloperationofholetypegaseousdetectorsatcryogenictemperatures AT peskovvladimir thesuccessfuloperationofholetypegaseousdetectorsatcryogenictemperatures AT picchipio thesuccessfuloperationofholetypegaseousdetectorsatcryogenictemperatures AT pietropaolof thesuccessfuloperationofholetypegaseousdetectorsatcryogenictemperatures AT tokanaif thesuccessfuloperationofholetypegaseousdetectorsatcryogenictemperatures AT perialeluciano successfuloperationofholetypegaseousdetectorsatcryogenictemperatures AT francketom successfuloperationofholetypegaseousdetectorsatcryogenictemperatures AT iacobaeusc successfuloperationofholetypegaseousdetectorsatcryogenictemperatures AT lundjensenbengt successfuloperationofholetypegaseousdetectorsatcryogenictemperatures AT pavlopoulosp successfuloperationofholetypegaseousdetectorsatcryogenictemperatures AT peskovvladimir successfuloperationofholetypegaseousdetectorsatcryogenictemperatures AT picchipio successfuloperationofholetypegaseousdetectorsatcryogenictemperatures AT pietropaolof successfuloperationofholetypegaseousdetectorsatcryogenictemperatures AT tokanaif successfuloperationofholetypegaseousdetectorsatcryogenictemperatures |