Cargando…

Radiation Tests of the VELO ECS and Analogue Repeater Mezzanines

The VELO front-end control system and analogue link is based on commercial components where the radiation tolerance is assured by a radiation qualification procedure. This note reports on the radiation qualification of the components required for the VELO ECS mezzanine and analogue repeater mezzanin...

Descripción completa

Detalles Bibliográficos
Autores principales: Eklund, L, Frei, R, Van der Gracht, A, Vollhardt, A
Lenguaje:eng
Publicado: 2006
Materias:
Acceso en línea:http://cds.cern.ch/record/926372
_version_ 1780909429092253696
author Eklund, L
Frei, R
Van der Gracht, A
Vollhardt, A
author_facet Eklund, L
Frei, R
Van der Gracht, A
Vollhardt, A
author_sort Eklund, L
collection CERN
description The VELO front-end control system and analogue link is based on commercial components where the radiation tolerance is assured by a radiation qualification procedure. This note reports on the radiation qualification of the components required for the VELO ECS mezzanine and analogue repeater mezzanines. They are located at the VELO vacuum vessel where the expected maximal dose is 73 kRad during 10 years of operation. The qualification was done by irradiating prototype circuits at the Paul Scherrer Institut in Villigen, Switzerland. The ECS mezzanine prototypes were irradiated to a dose of 780 kRad and the analogue driver test channels were irradiated to a dose of 600 kRad. All devices were fully functional after the irradiation and only a small increase in current consumption was observed.
id cern-926372
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2006
record_format invenio
spelling cern-9263722019-09-30T06:29:59Zhttp://cds.cern.ch/record/926372engEklund, LFrei, RVan der Gracht, AVollhardt, ARadiation Tests of the VELO ECS and Analogue Repeater MezzaninesDetectors and Experimental TechniquesThe VELO front-end control system and analogue link is based on commercial components where the radiation tolerance is assured by a radiation qualification procedure. This note reports on the radiation qualification of the components required for the VELO ECS mezzanine and analogue repeater mezzanines. They are located at the VELO vacuum vessel where the expected maximal dose is 73 kRad during 10 years of operation. The qualification was done by irradiating prototype circuits at the Paul Scherrer Institut in Villigen, Switzerland. The ECS mezzanine prototypes were irradiated to a dose of 780 kRad and the analogue driver test channels were irradiated to a dose of 600 kRad. All devices were fully functional after the irradiation and only a small increase in current consumption was observed.LHCb-2006-001CERN-LHCb-2006-001oai:cds.cern.ch:9263722006-02-02
spellingShingle Detectors and Experimental Techniques
Eklund, L
Frei, R
Van der Gracht, A
Vollhardt, A
Radiation Tests of the VELO ECS and Analogue Repeater Mezzanines
title Radiation Tests of the VELO ECS and Analogue Repeater Mezzanines
title_full Radiation Tests of the VELO ECS and Analogue Repeater Mezzanines
title_fullStr Radiation Tests of the VELO ECS and Analogue Repeater Mezzanines
title_full_unstemmed Radiation Tests of the VELO ECS and Analogue Repeater Mezzanines
title_short Radiation Tests of the VELO ECS and Analogue Repeater Mezzanines
title_sort radiation tests of the velo ecs and analogue repeater mezzanines
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/926372
work_keys_str_mv AT eklundl radiationtestsoftheveloecsandanaloguerepeatermezzanines
AT freir radiationtestsoftheveloecsandanaloguerepeatermezzanines
AT vandergrachta radiationtestsoftheveloecsandanaloguerepeatermezzanines
AT vollhardta radiationtestsoftheveloecsandanaloguerepeatermezzanines