Cargando…
Radiation Tests of the VELO ECS and Analogue Repeater Mezzanines
The VELO front-end control system and analogue link is based on commercial components where the radiation tolerance is assured by a radiation qualification procedure. This note reports on the radiation qualification of the components required for the VELO ECS mezzanine and analogue repeater mezzanin...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2006
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/926372 |
_version_ | 1780909429092253696 |
---|---|
author | Eklund, L Frei, R Van der Gracht, A Vollhardt, A |
author_facet | Eklund, L Frei, R Van der Gracht, A Vollhardt, A |
author_sort | Eklund, L |
collection | CERN |
description | The VELO front-end control system and analogue link is based on commercial components where the radiation tolerance is assured by a radiation qualification procedure. This note reports on the radiation qualification of the components required for the VELO ECS mezzanine and analogue repeater mezzanines. They are located at the VELO vacuum vessel where the expected maximal dose is 73 kRad during 10 years of operation. The qualification was done by irradiating prototype circuits at the Paul Scherrer Institut in Villigen, Switzerland. The ECS mezzanine prototypes were irradiated to a dose of 780 kRad and the analogue driver test channels were irradiated to a dose of 600 kRad. All devices were fully functional after the irradiation and only a small increase in current consumption was observed. |
id | cern-926372 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2006 |
record_format | invenio |
spelling | cern-9263722019-09-30T06:29:59Zhttp://cds.cern.ch/record/926372engEklund, LFrei, RVan der Gracht, AVollhardt, ARadiation Tests of the VELO ECS and Analogue Repeater MezzaninesDetectors and Experimental TechniquesThe VELO front-end control system and analogue link is based on commercial components where the radiation tolerance is assured by a radiation qualification procedure. This note reports on the radiation qualification of the components required for the VELO ECS mezzanine and analogue repeater mezzanines. They are located at the VELO vacuum vessel where the expected maximal dose is 73 kRad during 10 years of operation. The qualification was done by irradiating prototype circuits at the Paul Scherrer Institut in Villigen, Switzerland. The ECS mezzanine prototypes were irradiated to a dose of 780 kRad and the analogue driver test channels were irradiated to a dose of 600 kRad. All devices were fully functional after the irradiation and only a small increase in current consumption was observed.LHCb-2006-001CERN-LHCb-2006-001oai:cds.cern.ch:9263722006-02-02 |
spellingShingle | Detectors and Experimental Techniques Eklund, L Frei, R Van der Gracht, A Vollhardt, A Radiation Tests of the VELO ECS and Analogue Repeater Mezzanines |
title | Radiation Tests of the VELO ECS and Analogue Repeater Mezzanines |
title_full | Radiation Tests of the VELO ECS and Analogue Repeater Mezzanines |
title_fullStr | Radiation Tests of the VELO ECS and Analogue Repeater Mezzanines |
title_full_unstemmed | Radiation Tests of the VELO ECS and Analogue Repeater Mezzanines |
title_short | Radiation Tests of the VELO ECS and Analogue Repeater Mezzanines |
title_sort | radiation tests of the velo ecs and analogue repeater mezzanines |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/926372 |
work_keys_str_mv | AT eklundl radiationtestsoftheveloecsandanaloguerepeatermezzanines AT freir radiationtestsoftheveloecsandanaloguerepeatermezzanines AT vandergrachta radiationtestsoftheveloecsandanaloguerepeatermezzanines AT vollhardta radiationtestsoftheveloecsandanaloguerepeatermezzanines |