Cargando…
Calculation of Residual Dose Rates and Intervention Scenarios for the LHC Beam Cleaning Insertions-Constraints and Optimization
Radiation protection of the personnel who will perform interventions in the LHC Beam Cleaning Insertions is mandatory and includes the design of equipment and the establishment of work procedures. Residual dose rates due to activated equipment are expected to reach significant values such that any m...
Autores principales: | , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2005
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/926952 |
_version_ | 1780909435547287552 |
---|---|
author | Brugger, Markus Aberle, Oliver Assmann, R W Forkel-Wirth, Doris Menzel, Hans Gregor Roesler, Stefan Vincke, Helmut H |
author_facet | Brugger, Markus Aberle, Oliver Assmann, R W Forkel-Wirth, Doris Menzel, Hans Gregor Roesler, Stefan Vincke, Helmut H |
author_sort | Brugger, Markus |
collection | CERN |
description | Radiation protection of the personnel who will perform interventions in the LHC Beam Cleaning Insertions is mandatory and includes the design of equipment and the establishment of work procedures. Residual dose rates due to activated equipment are expected to reach significant values such that any maintenance has to be planned and optimized in advance. Three-dimensional maps of dose equivalent rates at different cooling times after operation of the LHC have been calculated with FLUKA. The simulations are based on an explicit calculation of induced radioactivity and of the transport of the radiation from the radioactive decay. The paper summarizes the results for the Beam Cleaning Insertions and discusses the estimation of individual and collective doses received by personnel during critical interventions, such as the exchange of a collimator or the installation of Phase 2. The given examples outline the potential and the need to optimize, in an iterative way, the design of components as well as the layout of the beam cleaning insertions. Furthermore, results of measurements and simulations of residual dose rates for a collimator test recently performed at the SPS are presented. |
id | cern-926952 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2005 |
record_format | invenio |
spelling | cern-9269522022-08-17T13:36:05Zhttp://cds.cern.ch/record/926952engBrugger, MarkusAberle, OliverAssmann, R WForkel-Wirth, DorisMenzel, Hans GregorRoesler, StefanVincke, Helmut HCalculation of Residual Dose Rates and Intervention Scenarios for the LHC Beam Cleaning Insertions-Constraints and OptimizationAccelerators and Storage RingsRadiation protection of the personnel who will perform interventions in the LHC Beam Cleaning Insertions is mandatory and includes the design of equipment and the establishment of work procedures. Residual dose rates due to activated equipment are expected to reach significant values such that any maintenance has to be planned and optimized in advance. Three-dimensional maps of dose equivalent rates at different cooling times after operation of the LHC have been calculated with FLUKA. The simulations are based on an explicit calculation of induced radioactivity and of the transport of the radiation from the radioactive decay. The paper summarizes the results for the Beam Cleaning Insertions and discusses the estimation of individual and collective doses received by personnel during critical interventions, such as the exchange of a collimator or the installation of Phase 2. The given examples outline the potential and the need to optimize, in an iterative way, the design of components as well as the layout of the beam cleaning insertions. Furthermore, results of measurements and simulations of residual dose rates for a collimator test recently performed at the SPS are presented.oai:cds.cern.ch:9269522005 |
spellingShingle | Accelerators and Storage Rings Brugger, Markus Aberle, Oliver Assmann, R W Forkel-Wirth, Doris Menzel, Hans Gregor Roesler, Stefan Vincke, Helmut H Calculation of Residual Dose Rates and Intervention Scenarios for the LHC Beam Cleaning Insertions-Constraints and Optimization |
title | Calculation of Residual Dose Rates and Intervention Scenarios for the LHC Beam Cleaning Insertions-Constraints and Optimization |
title_full | Calculation of Residual Dose Rates and Intervention Scenarios for the LHC Beam Cleaning Insertions-Constraints and Optimization |
title_fullStr | Calculation of Residual Dose Rates and Intervention Scenarios for the LHC Beam Cleaning Insertions-Constraints and Optimization |
title_full_unstemmed | Calculation of Residual Dose Rates and Intervention Scenarios for the LHC Beam Cleaning Insertions-Constraints and Optimization |
title_short | Calculation of Residual Dose Rates and Intervention Scenarios for the LHC Beam Cleaning Insertions-Constraints and Optimization |
title_sort | calculation of residual dose rates and intervention scenarios for the lhc beam cleaning insertions-constraints and optimization |
topic | Accelerators and Storage Rings |
url | http://cds.cern.ch/record/926952 |
work_keys_str_mv | AT bruggermarkus calculationofresidualdoseratesandinterventionscenariosforthelhcbeamcleaninginsertionsconstraintsandoptimization AT aberleoliver calculationofresidualdoseratesandinterventionscenariosforthelhcbeamcleaninginsertionsconstraintsandoptimization AT assmannrw calculationofresidualdoseratesandinterventionscenariosforthelhcbeamcleaninginsertionsconstraintsandoptimization AT forkelwirthdoris calculationofresidualdoseratesandinterventionscenariosforthelhcbeamcleaninginsertionsconstraintsandoptimization AT menzelhansgregor calculationofresidualdoseratesandinterventionscenariosforthelhcbeamcleaninginsertionsconstraintsandoptimization AT roeslerstefan calculationofresidualdoseratesandinterventionscenariosforthelhcbeamcleaninginsertionsconstraintsandoptimization AT vinckehelmuth calculationofresidualdoseratesandinterventionscenariosforthelhcbeamcleaninginsertionsconstraintsandoptimization |