Cargando…

Beam Loss Monitoring System for the LHC

One of the most critical elements for the protection of CERN's Large Hadron Collider (LHC) is its beam loss monitoring (BLM) system. It must prevent the superconducting magnets from quenching and protect the machine components from damages, as a result of critical beam losses. By measuring the...

Descripción completa

Detalles Bibliográficos
Autores principales: Holzer, E B, Dehning, B, Effinger, E, Emery, J, Ferioli, G, González, J L, Gschwendtner, E, Guaglio, G, Hodgson, M, Kramer, Daniel, Leitner, R, Ponce, L, Prieto, V, Stockner, M, Zamantzas, C
Lenguaje:eng
Publicado: 2005
Materias:
Acceso en línea:http://cds.cern.ch/record/930275
_version_ 1780909515375378432
author Holzer, E B
Dehning, B
Effinger, E
Emery, J
Ferioli, G
González, J L
Gschwendtner, E
Guaglio, G
Hodgson, M
Kramer, Daniel
Leitner, R
Ponce, L
Prieto, V
Stockner, M
Zamantzas, C
author_facet Holzer, E B
Dehning, B
Effinger, E
Emery, J
Ferioli, G
González, J L
Gschwendtner, E
Guaglio, G
Hodgson, M
Kramer, Daniel
Leitner, R
Ponce, L
Prieto, V
Stockner, M
Zamantzas, C
author_sort Holzer, E B
collection CERN
description One of the most critical elements for the protection of CERN's Large Hadron Collider (LHC) is its beam loss monitoring (BLM) system. It must prevent the superconducting magnets from quenching and protect the machine components from damages, as a result of critical beam losses. By measuring the loss pattern, the BLM system helps to identify the loss mechanism. Special monitors will be used for the setup and control of the collimators. The specification for the BLM system includes a very high reliability (tolerable failure rate of 10.-7 per hour) and a high dynamic range of 10.8 (10.13 at certain locations) of the particle fluencies to be measured. In addition, a wide range of integration times (40 micro/s to 84s) and a fast (one turn) trigger generation for the dump signal are required. This paper describes the complete design of the BLM system, including the monitor types (ionization chambers and secondary emission monitors), the design of the analogue and digital readout electronics as well as the data links and the trigger decision logic.
id cern-930275
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2005
record_format invenio
spelling cern-9302752019-09-30T06:29:59Zhttp://cds.cern.ch/record/930275engHolzer, E BDehning, BEffinger, EEmery, JFerioli, GGonzález, J LGschwendtner, EGuaglio, GHodgson, MKramer, DanielLeitner, RPonce, LPrieto, VStockner, MZamantzas, CBeam Loss Monitoring System for the LHCAccelerators and Storage RingsOne of the most critical elements for the protection of CERN's Large Hadron Collider (LHC) is its beam loss monitoring (BLM) system. It must prevent the superconducting magnets from quenching and protect the machine components from damages, as a result of critical beam losses. By measuring the loss pattern, the BLM system helps to identify the loss mechanism. Special monitors will be used for the setup and control of the collimators. The specification for the BLM system includes a very high reliability (tolerable failure rate of 10.-7 per hour) and a high dynamic range of 10.8 (10.13 at certain locations) of the particle fluencies to be measured. In addition, a wide range of integration times (40 micro/s to 84s) and a fast (one turn) trigger generation for the dump signal are required. This paper describes the complete design of the BLM system, including the monitor types (ionization chambers and secondary emission monitors), the design of the analogue and digital readout electronics as well as the data links and the trigger decision logic.CERN-AB-2006-009oai:cds.cern.ch:9302752005-09-01
spellingShingle Accelerators and Storage Rings
Holzer, E B
Dehning, B
Effinger, E
Emery, J
Ferioli, G
González, J L
Gschwendtner, E
Guaglio, G
Hodgson, M
Kramer, Daniel
Leitner, R
Ponce, L
Prieto, V
Stockner, M
Zamantzas, C
Beam Loss Monitoring System for the LHC
title Beam Loss Monitoring System for the LHC
title_full Beam Loss Monitoring System for the LHC
title_fullStr Beam Loss Monitoring System for the LHC
title_full_unstemmed Beam Loss Monitoring System for the LHC
title_short Beam Loss Monitoring System for the LHC
title_sort beam loss monitoring system for the lhc
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/930275
work_keys_str_mv AT holzereb beamlossmonitoringsystemforthelhc
AT dehningb beamlossmonitoringsystemforthelhc
AT effingere beamlossmonitoringsystemforthelhc
AT emeryj beamlossmonitoringsystemforthelhc
AT feriolig beamlossmonitoringsystemforthelhc
AT gonzalezjl beamlossmonitoringsystemforthelhc
AT gschwendtnere beamlossmonitoringsystemforthelhc
AT guagliog beamlossmonitoringsystemforthelhc
AT hodgsonm beamlossmonitoringsystemforthelhc
AT kramerdaniel beamlossmonitoringsystemforthelhc
AT leitnerr beamlossmonitoringsystemforthelhc
AT poncel beamlossmonitoringsystemforthelhc
AT prietov beamlossmonitoringsystemforthelhc
AT stocknerm beamlossmonitoringsystemforthelhc
AT zamantzasc beamlossmonitoringsystemforthelhc