Cargando…
Study of the Sagitta Resolution of MDT-Chambers
The cosmic ray measurement facility in Garching, Germany, provides a good environment to validate the Geant4 simulation of the MDT-chambers with real data. The sagitta resolution of the muon tracks, reconstructed with the three MDT-chambers of this setup, allows a meaningful test of this comparison....
Autores principales: | , , |
---|---|
Lenguaje: | eng |
Publicado: |
2006
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/934494 |
_version_ | 1780909644022022144 |
---|---|
author | Schott, Matthias Duckeck, G Obermaier, Matthias |
author_facet | Schott, Matthias Duckeck, G Obermaier, Matthias |
author_sort | Schott, Matthias |
collection | CERN |
description | The cosmic ray measurement facility in Garching, Germany, provides a good environment to validate the Geant4 simulation of the MDT-chambers with real data. The sagitta resolution of the muon tracks, reconstructed with the three MDT-chambers of this setup, allows a meaningful test of this comparison. The sagitta resolution of the measurement facility was measured with cosmic muons recorded between 2004 and 2005. This measured resolution was reproduced to a very high accuracy within a detailed Geant4 simulation of the measurement facility and the MDT-chambers. Given this validated simulation, other effects of the sagitta and momentum resolution of the MDT-chambers in the cosmic ray measurement facility, in the ATLAS detector and the H8-testbeam construction are studied. In particular effects of multiple scattering, single tube resolution and alignment are discussed. |
id | cern-934494 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2006 |
record_format | invenio |
spelling | cern-9344942019-09-30T06:29:59Zhttp://cds.cern.ch/record/934494engSchott, MatthiasDuckeck, GObermaier, MatthiasStudy of the Sagitta Resolution of MDT-ChambersDetectors and Experimental TechniquesThe cosmic ray measurement facility in Garching, Germany, provides a good environment to validate the Geant4 simulation of the MDT-chambers with real data. The sagitta resolution of the muon tracks, reconstructed with the three MDT-chambers of this setup, allows a meaningful test of this comparison. The sagitta resolution of the measurement facility was measured with cosmic muons recorded between 2004 and 2005. This measured resolution was reproduced to a very high accuracy within a detailed Geant4 simulation of the measurement facility and the MDT-chambers. Given this validated simulation, other effects of the sagitta and momentum resolution of the MDT-chambers in the cosmic ray measurement facility, in the ATLAS detector and the H8-testbeam construction are studied. In particular effects of multiple scattering, single tube resolution and alignment are discussed.ATL-MUON-PUB-2006-010ATL-COM-MUON-2006-004oai:cds.cern.ch:9344942006-03-15 |
spellingShingle | Detectors and Experimental Techniques Schott, Matthias Duckeck, G Obermaier, Matthias Study of the Sagitta Resolution of MDT-Chambers |
title | Study of the Sagitta Resolution of MDT-Chambers |
title_full | Study of the Sagitta Resolution of MDT-Chambers |
title_fullStr | Study of the Sagitta Resolution of MDT-Chambers |
title_full_unstemmed | Study of the Sagitta Resolution of MDT-Chambers |
title_short | Study of the Sagitta Resolution of MDT-Chambers |
title_sort | study of the sagitta resolution of mdt-chambers |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/934494 |
work_keys_str_mv | AT schottmatthias studyofthesagittaresolutionofmdtchambers AT duckeckg studyofthesagittaresolutionofmdtchambers AT obermaiermatthias studyofthesagittaresolutionofmdtchambers |