Cargando…
Scintillation counter with MRS APD light readout
START, a high-efficiency and low-noise scintillation detector for ionizing particles, was developed for the purpose of creating a high-granular system for triggering cosmic muons. Scintillation light in START is detected by MRS APDs (Avalanche Photo-Diodes with Metal-Resistance-Semiconductor structu...
Autores principales: | , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2006
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1016/j.nima.2004.10.026 http://cds.cern.ch/record/938821 |
_version_ | 1780909721525420032 |
---|---|
author | Akindinov, A. Grishuk, Yu. Malkevich, D. Martemyanov, A. Ryabinin, M. Smirnitsky, A. Voloshin, K. Bondarenko, G. Golovin, V. Grigoriev, E. |
author_facet | Akindinov, A. Grishuk, Yu. Malkevich, D. Martemyanov, A. Ryabinin, M. Smirnitsky, A. Voloshin, K. Bondarenko, G. Golovin, V. Grigoriev, E. |
author_sort | Akindinov, A. |
collection | CERN |
description | START, a high-efficiency and low-noise scintillation detector for ionizing particles, was developed for the purpose of creating a high-granular system for triggering cosmic muons. Scintillation light in START is detected by MRS APDs (Avalanche Photo-Diodes with Metal-Resistance-Semiconductor structure), operated in the Geiger mode, which have 1 mm^2 sensitive areas. START is assembled from a 15 x 15 x 1 cm^3 scintillating plastic plate, two MRS APDs and two pieces of wavelength-shifting optical fiber stacked in circular coils inside the plastic. The front-end electronic card is mounted directly on the detector. Tests with START have confirmed its operational consistency, over 99% efficiency of MIP registration and good homogeneity. START demonstrates a low intrinsic noise of about 10^{-2} Hz. If these detectors are to be mass-produced, the cost of a mosaic array of STARTs is estimated at a moderate level of 2-3 kUSD/m^2. |
id | cern-938821 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2006 |
record_format | invenio |
spelling | cern-9388212023-03-14T18:10:44Zdoi:10.1016/j.nima.2004.10.026http://cds.cern.ch/record/938821engAkindinov, A.Grishuk, Yu.Malkevich, D.Martemyanov, A.Ryabinin, M.Smirnitsky, A.Voloshin, K.Bondarenko, G.Golovin, V.Grigoriev, E.Scintillation counter with MRS APD light readoutOther Fields of PhysicsSTART, a high-efficiency and low-noise scintillation detector for ionizing particles, was developed for the purpose of creating a high-granular system for triggering cosmic muons. Scintillation light in START is detected by MRS APDs (Avalanche Photo-Diodes with Metal-Resistance-Semiconductor structure), operated in the Geiger mode, which have 1 mm^2 sensitive areas. START is assembled from a 15 x 15 x 1 cm^3 scintillating plastic plate, two MRS APDs and two pieces of wavelength-shifting optical fiber stacked in circular coils inside the plastic. The front-end electronic card is mounted directly on the detector. Tests with START have confirmed its operational consistency, over 99% efficiency of MIP registration and good homogeneity. START demonstrates a low intrinsic noise of about 10^{-2} Hz. If these detectors are to be mass-produced, the cost of a mosaic array of STARTs is estimated at a moderate level of 2-3 kUSD/m^2.START, a high-efficiency and low-noise scintillation detector for ionizing particles, was developed for the purpose of creating a high-granular system for triggering cosmic muons. Scintillation light in START is detected by MRS APDs (Avalanche Photo-Diodes with Metal-Resistance-Semiconductor structure), operated in the Geiger mode, which have 1 mm^2 sensitive areas. START is assembled from a 15 x 15 x 1 cm^3 scintillating plastic plate, two MRS APDs and two pieces of wavelength-shifting optical fiber stacked in circular coils inside the plastic. The front-end electronic card is mounted directly on the detector. Tests with START have confirmed its operational consistency, over 99% efficiency of MIP registration and good homogeneity. START demonstrates a low intrinsic noise of about 10^{-2} Hz. If these detectors are to be mass-produced, the cost of a mosaic array of STARTs is estimated at a moderate level of 2-3 kUSD/m^2.physics/0603224oai:cds.cern.ch:9388212006-03-27 |
spellingShingle | Other Fields of Physics Akindinov, A. Grishuk, Yu. Malkevich, D. Martemyanov, A. Ryabinin, M. Smirnitsky, A. Voloshin, K. Bondarenko, G. Golovin, V. Grigoriev, E. Scintillation counter with MRS APD light readout |
title | Scintillation counter with MRS APD light readout |
title_full | Scintillation counter with MRS APD light readout |
title_fullStr | Scintillation counter with MRS APD light readout |
title_full_unstemmed | Scintillation counter with MRS APD light readout |
title_short | Scintillation counter with MRS APD light readout |
title_sort | scintillation counter with mrs apd light readout |
topic | Other Fields of Physics |
url | https://dx.doi.org/10.1016/j.nima.2004.10.026 http://cds.cern.ch/record/938821 |
work_keys_str_mv | AT akindinova scintillationcounterwithmrsapdlightreadout AT grishukyu scintillationcounterwithmrsapdlightreadout AT malkevichd scintillationcounterwithmrsapdlightreadout AT martemyanova scintillationcounterwithmrsapdlightreadout AT ryabininm scintillationcounterwithmrsapdlightreadout AT smirnitskya scintillationcounterwithmrsapdlightreadout AT voloshink scintillationcounterwithmrsapdlightreadout AT bondarenkog scintillationcounterwithmrsapdlightreadout AT golovinv scintillationcounterwithmrsapdlightreadout AT grigorieve scintillationcounterwithmrsapdlightreadout |