Cargando…

Scintillation counter with MRS APD light readout

START, a high-efficiency and low-noise scintillation detector for ionizing particles, was developed for the purpose of creating a high-granular system for triggering cosmic muons. Scintillation light in START is detected by MRS APDs (Avalanche Photo-Diodes with Metal-Resistance-Semiconductor structu...

Descripción completa

Detalles Bibliográficos
Autores principales: Akindinov, A., Grishuk, Yu., Malkevich, D., Martemyanov, A., Ryabinin, M., Smirnitsky, A., Voloshin, K., Bondarenko, G., Golovin, V., Grigoriev, E.
Lenguaje:eng
Publicado: 2006
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2004.10.026
http://cds.cern.ch/record/938821
_version_ 1780909721525420032
author Akindinov, A.
Grishuk, Yu.
Malkevich, D.
Martemyanov, A.
Ryabinin, M.
Smirnitsky, A.
Voloshin, K.
Bondarenko, G.
Golovin, V.
Grigoriev, E.
author_facet Akindinov, A.
Grishuk, Yu.
Malkevich, D.
Martemyanov, A.
Ryabinin, M.
Smirnitsky, A.
Voloshin, K.
Bondarenko, G.
Golovin, V.
Grigoriev, E.
author_sort Akindinov, A.
collection CERN
description START, a high-efficiency and low-noise scintillation detector for ionizing particles, was developed for the purpose of creating a high-granular system for triggering cosmic muons. Scintillation light in START is detected by MRS APDs (Avalanche Photo-Diodes with Metal-Resistance-Semiconductor structure), operated in the Geiger mode, which have 1 mm^2 sensitive areas. START is assembled from a 15 x 15 x 1 cm^3 scintillating plastic plate, two MRS APDs and two pieces of wavelength-shifting optical fiber stacked in circular coils inside the plastic. The front-end electronic card is mounted directly on the detector. Tests with START have confirmed its operational consistency, over 99% efficiency of MIP registration and good homogeneity. START demonstrates a low intrinsic noise of about 10^{-2} Hz. If these detectors are to be mass-produced, the cost of a mosaic array of STARTs is estimated at a moderate level of 2-3 kUSD/m^2.
id cern-938821
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2006
record_format invenio
spelling cern-9388212023-03-14T18:10:44Zdoi:10.1016/j.nima.2004.10.026http://cds.cern.ch/record/938821engAkindinov, A.Grishuk, Yu.Malkevich, D.Martemyanov, A.Ryabinin, M.Smirnitsky, A.Voloshin, K.Bondarenko, G.Golovin, V.Grigoriev, E.Scintillation counter with MRS APD light readoutOther Fields of PhysicsSTART, a high-efficiency and low-noise scintillation detector for ionizing particles, was developed for the purpose of creating a high-granular system for triggering cosmic muons. Scintillation light in START is detected by MRS APDs (Avalanche Photo-Diodes with Metal-Resistance-Semiconductor structure), operated in the Geiger mode, which have 1 mm^2 sensitive areas. START is assembled from a 15 x 15 x 1 cm^3 scintillating plastic plate, two MRS APDs and two pieces of wavelength-shifting optical fiber stacked in circular coils inside the plastic. The front-end electronic card is mounted directly on the detector. Tests with START have confirmed its operational consistency, over 99% efficiency of MIP registration and good homogeneity. START demonstrates a low intrinsic noise of about 10^{-2} Hz. If these detectors are to be mass-produced, the cost of a mosaic array of STARTs is estimated at a moderate level of 2-3 kUSD/m^2.START, a high-efficiency and low-noise scintillation detector for ionizing particles, was developed for the purpose of creating a high-granular system for triggering cosmic muons. Scintillation light in START is detected by MRS APDs (Avalanche Photo-Diodes with Metal-Resistance-Semiconductor structure), operated in the Geiger mode, which have 1 mm^2 sensitive areas. START is assembled from a 15 x 15 x 1 cm^3 scintillating plastic plate, two MRS APDs and two pieces of wavelength-shifting optical fiber stacked in circular coils inside the plastic. The front-end electronic card is mounted directly on the detector. Tests with START have confirmed its operational consistency, over 99% efficiency of MIP registration and good homogeneity. START demonstrates a low intrinsic noise of about 10^{-2} Hz. If these detectors are to be mass-produced, the cost of a mosaic array of STARTs is estimated at a moderate level of 2-3 kUSD/m^2.physics/0603224oai:cds.cern.ch:9388212006-03-27
spellingShingle Other Fields of Physics
Akindinov, A.
Grishuk, Yu.
Malkevich, D.
Martemyanov, A.
Ryabinin, M.
Smirnitsky, A.
Voloshin, K.
Bondarenko, G.
Golovin, V.
Grigoriev, E.
Scintillation counter with MRS APD light readout
title Scintillation counter with MRS APD light readout
title_full Scintillation counter with MRS APD light readout
title_fullStr Scintillation counter with MRS APD light readout
title_full_unstemmed Scintillation counter with MRS APD light readout
title_short Scintillation counter with MRS APD light readout
title_sort scintillation counter with mrs apd light readout
topic Other Fields of Physics
url https://dx.doi.org/10.1016/j.nima.2004.10.026
http://cds.cern.ch/record/938821
work_keys_str_mv AT akindinova scintillationcounterwithmrsapdlightreadout
AT grishukyu scintillationcounterwithmrsapdlightreadout
AT malkevichd scintillationcounterwithmrsapdlightreadout
AT martemyanova scintillationcounterwithmrsapdlightreadout
AT ryabininm scintillationcounterwithmrsapdlightreadout
AT smirnitskya scintillationcounterwithmrsapdlightreadout
AT voloshink scintillationcounterwithmrsapdlightreadout
AT bondarenkog scintillationcounterwithmrsapdlightreadout
AT golovinv scintillationcounterwithmrsapdlightreadout
AT grigorieve scintillationcounterwithmrsapdlightreadout