ATLAS Combined Testbeam: Computation and Validation of the Electronic Calibration Constants for the Electromagnetic Calorimeter

From July to November 2004, a full slice of the ATLAS barrel detector was studied in testbeam. A complete electromagnetic barrel module was used, read by the final electronics and operated by ATLAS TDAQ software. This note describes in details the electronic calibration procedure and the cell energy...

Descripción completa

Detalles Bibliográficos
Autores principales: Aleksa, Martin, Delmastro, M, Fanti, M, Lafaye, R, Lampl, W, Laplace, S, Prieur, D, Tarrade, F, Wingerter-Seez, I
Lenguaje:eng
Publicado: 2006
Materias:
Acceso en línea:http://cds.cern.ch/record/942528
_version_ 1780909832026456064
author Aleksa, Martin
Delmastro, M
Fanti, M
Lafaye, R
Lampl, W
Laplace, S
Prieur, D
Tarrade, F
Wingerter-Seez, I
author_facet Aleksa, Martin
Delmastro, M
Fanti, M
Lafaye, R
Lampl, W
Laplace, S
Prieur, D
Tarrade, F
Wingerter-Seez, I
author_sort Aleksa, Martin
collection CERN
description From July to November 2004, a full slice of the ATLAS barrel detector was studied in testbeam. A complete electromagnetic barrel module was used, read by the final electronics and operated by ATLAS TDAQ software. This note describes in details the electronic calibration procedure and the cell energy reconstruction: each step of the procedure and its associated software is explicitly described. The general calibration procedure is very similar to the one applied in previous barrel and endcap standalone testbeams. Emphasis is put on tools developed in the context of the combined testbeam which can be used for commissioning and operation of the calorimeters in ATLAS. Many validation studies were performed on each calibration constant. Previously unobserved effects such as the FEB temperature dependence of some constants were observed. Overall, the calibration performances are at the expected level.
id cern-942528
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2006
record_format invenio
spelling cern-9425282019-09-30T06:29:59Zhttp://cds.cern.ch/record/942528engAleksa, MartinDelmastro, MFanti, MLafaye, RLampl, WLaplace, SPrieur, DTarrade, FWingerter-Seez, IATLAS Combined Testbeam: Computation and Validation of the Electronic Calibration Constants for the Electromagnetic CalorimeterDetectors and Experimental TechniquesFrom July to November 2004, a full slice of the ATLAS barrel detector was studied in testbeam. A complete electromagnetic barrel module was used, read by the final electronics and operated by ATLAS TDAQ software. This note describes in details the electronic calibration procedure and the cell energy reconstruction: each step of the procedure and its associated software is explicitly described. The general calibration procedure is very similar to the one applied in previous barrel and endcap standalone testbeams. Emphasis is put on tools developed in the context of the combined testbeam which can be used for commissioning and operation of the calorimeters in ATLAS. Many validation studies were performed on each calibration constant. Previously unobserved effects such as the FEB temperature dependence of some constants were observed. Overall, the calibration performances are at the expected level.ATL-LARG-PUB-2006-003ATL-COM-LARG-2006-003oai:cds.cern.ch:9425282006-04-18
spellingShingle Detectors and Experimental Techniques
Aleksa, Martin
Delmastro, M
Fanti, M
Lafaye, R
Lampl, W
Laplace, S
Prieur, D
Tarrade, F
Wingerter-Seez, I
ATLAS Combined Testbeam: Computation and Validation of the Electronic Calibration Constants for the Electromagnetic Calorimeter
title ATLAS Combined Testbeam: Computation and Validation of the Electronic Calibration Constants for the Electromagnetic Calorimeter
title_full ATLAS Combined Testbeam: Computation and Validation of the Electronic Calibration Constants for the Electromagnetic Calorimeter
title_fullStr ATLAS Combined Testbeam: Computation and Validation of the Electronic Calibration Constants for the Electromagnetic Calorimeter
title_full_unstemmed ATLAS Combined Testbeam: Computation and Validation of the Electronic Calibration Constants for the Electromagnetic Calorimeter
title_short ATLAS Combined Testbeam: Computation and Validation of the Electronic Calibration Constants for the Electromagnetic Calorimeter
title_sort atlas combined testbeam: computation and validation of the electronic calibration constants for the electromagnetic calorimeter
topic Detectors and Experimental Techniques
url http://cds.cern.ch/record/942528
work_keys_str_mv AT aleksamartin atlascombinedtestbeamcomputationandvalidationoftheelectroniccalibrationconstantsfortheelectromagneticcalorimeter
AT delmastrom atlascombinedtestbeamcomputationandvalidationoftheelectroniccalibrationconstantsfortheelectromagneticcalorimeter
AT fantim atlascombinedtestbeamcomputationandvalidationoftheelectroniccalibrationconstantsfortheelectromagneticcalorimeter
AT lafayer atlascombinedtestbeamcomputationandvalidationoftheelectroniccalibrationconstantsfortheelectromagneticcalorimeter
AT lamplw atlascombinedtestbeamcomputationandvalidationoftheelectroniccalibrationconstantsfortheelectromagneticcalorimeter
AT laplaces atlascombinedtestbeamcomputationandvalidationoftheelectroniccalibrationconstantsfortheelectromagneticcalorimeter
AT prieurd atlascombinedtestbeamcomputationandvalidationoftheelectroniccalibrationconstantsfortheelectromagneticcalorimeter
AT tarradef atlascombinedtestbeamcomputationandvalidationoftheelectroniccalibrationconstantsfortheelectromagneticcalorimeter
AT wingerterseezi atlascombinedtestbeamcomputationandvalidationoftheelectroniccalibrationconstantsfortheelectromagneticcalorimeter