Study of MDT calibration constants using H8 testbeam data of year 2004
In year 2004 Atlas performed a long campaign of test beam data taking at the H8 Cern beam. Two sectors of the barrel and endcap regions of the Muon Spectrometer were exposed to the beam and large amount of data were collected in well defined and controlled operating conditions. This allowed a carefu...
Autores principales: | , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2006
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/968565 |
_version_ | 1780910467932225536 |
---|---|
author | Baroncelli, T Bianchi, R M Di Luise, S Passeri, A Petrucci, F Spogli, L |
author_facet | Baroncelli, T Bianchi, R M Di Luise, S Passeri, A Petrucci, F Spogli, L |
author_sort | Baroncelli, T |
collection | CERN |
description | In year 2004 Atlas performed a long campaign of test beam data taking at the H8 Cern beam. Two sectors of the barrel and endcap regions of the Muon Spectrometer were exposed to the beam and large amount of data were collected in well defined and controlled operating conditions. This allowed a careful study on MDT drift properties. A better understanding of the calibration constants, of their definition and determination and of the criteria for their acceptance has been obtained. Systematic effects and time stability of the constants have also been studied. |
id | cern-968565 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2006 |
record_format | invenio |
spelling | cern-9685652019-09-30T06:29:59Zhttp://cds.cern.ch/record/968565engBaroncelli, TBianchi, R MDi Luise, SPasseri, APetrucci, FSpogli, LStudy of MDT calibration constants using H8 testbeam data of year 2004Detectors and Experimental TechniquesIn year 2004 Atlas performed a long campaign of test beam data taking at the H8 Cern beam. Two sectors of the barrel and endcap regions of the Muon Spectrometer were exposed to the beam and large amount of data were collected in well defined and controlled operating conditions. This allowed a careful study on MDT drift properties. A better understanding of the calibration constants, of their definition and determination and of the criteria for their acceptance has been obtained. Systematic effects and time stability of the constants have also been studied.ATL-MUON-PUB-2007-004ATL-COM-MUON-2006-015oai:cds.cern.ch:9685652006-07-05 |
spellingShingle | Detectors and Experimental Techniques Baroncelli, T Bianchi, R M Di Luise, S Passeri, A Petrucci, F Spogli, L Study of MDT calibration constants using H8 testbeam data of year 2004 |
title | Study of MDT calibration constants using H8 testbeam data of year 2004 |
title_full | Study of MDT calibration constants using H8 testbeam data of year 2004 |
title_fullStr | Study of MDT calibration constants using H8 testbeam data of year 2004 |
title_full_unstemmed | Study of MDT calibration constants using H8 testbeam data of year 2004 |
title_short | Study of MDT calibration constants using H8 testbeam data of year 2004 |
title_sort | study of mdt calibration constants using h8 testbeam data of year 2004 |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/968565 |
work_keys_str_mv | AT baroncellit studyofmdtcalibrationconstantsusingh8testbeamdataofyear2004 AT bianchirm studyofmdtcalibrationconstantsusingh8testbeamdataofyear2004 AT diluises studyofmdtcalibrationconstantsusingh8testbeamdataofyear2004 AT passeria studyofmdtcalibrationconstantsusingh8testbeamdataofyear2004 AT petruccif studyofmdtcalibrationconstantsusingh8testbeamdataofyear2004 AT spoglil studyofmdtcalibrationconstantsusingh8testbeamdataofyear2004 |