Normal-Conducting Separation and Compensation Dipoles for the LHC Experimental Insertions

The experimental insertions of the LHC make use of normal-conducting magnets to provide for part of the beam separation and to compensate the effect of two large spectrometer dipoles. Three different types with respect to the length were designed and are based on the same type of lamination. The mai...

Descripción completa

Detalles Bibliográficos
Autores principales: Ramberger, S, Bidon, S, Cornuet, D, Gérard, D, Gurov, D, Hans, O, Kalbreier, Willi, Kiselev, O, Morozov, I, Ogurtsov, A, Petrov, V, de Rijk, G, Ruvinsky, E, Sukhanov, A, Zhilayev, K
Lenguaje:eng
Publicado: 2006
Materias:
Acceso en línea:https://dx.doi.org/10.1109/TASC.2005.869553
http://cds.cern.ch/record/970361
Descripción
Sumario:The experimental insertions of the LHC make use of normal-conducting magnets to provide for part of the beam separation and to compensate the effect of two large spectrometer dipoles. Three different types with respect to the length were designed and are based on the same type of lamination. The main type of magnet MBXW has a core length of 3.4 m while the MBXWT and MBXWS magnets are 1.5 m and 0.75 m long versions respectively. The magnet design was done in collaboration between CERN and BINP and the dipole magnets are produced by BINP. So far all three MBXWS magnets, all three MBXWT magnets and fifteen of twenty-nine MBXW magnets have been manufactured and delivered to CERN. The report presents the main design issues and results of the acceptance tests including mechanical, electrical and magnetic field measurements.