Cargando…

New neutron detector based on Micromegas technology for ADS projects

A new neutron detector based on Micromegas technology has been developed for the measurement of the simulated neutron spectrum in the ADS project. After the presentation of simulated neutron spectra obtained in the interaction of 140 MeV protons with the spallation target inside the TRIGA core, a fu...

Descripción completa

Detalles Bibliográficos
Autores principales: Andriamonje, Samuel, Andriamonje, Gregory, Aune, Stephan, Ban, Gilles, Breaud, Stephane, Blandin, Christophe, Ferrer, Esther, Geslot, Benoit, Giganon, Arnaud, Giomataris, Ioannis, Jammes, Christian, Kadi, Yacine, Laborie, Philippe, Lecolley, Jean Francois, Pancin, Julien, Riallot, Marc, Rosa, Roberto, Sarchiapone, Lucia, Steckmeyer, Jean Claude, Tillier, Joel
Lenguaje:eng
Publicado: 2006
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.nima.2006.02.048
http://cds.cern.ch/record/970890
Descripción
Sumario:A new neutron detector based on Micromegas technology has been developed for the measurement of the simulated neutron spectrum in the ADS project. After the presentation of simulated neutron spectra obtained in the interaction of 140 MeV protons with the spallation target inside the TRIGA core, a full description of the new detector configuration is given. The advantage of this detector compared to conventional neutron flux detectors and the results obtained with the first prototype at the CELINA 14 MeV neutron source facility at CEA-Cadarache are presented. The future developments of operational Piccolo-Micromegas for fast neutron reactors are also described.