Time resolved spectrometry on the CLIC Test Facility 3
The high charge (>6ìC) electron beam produced in the CLIC Test Facility 3 (CTF3) is accelerated in fully beam loaded cavities. To be able to measure the resulting strong transient effects, the time evolution of the beam energy and its energy spread must be determined with at least 50MHz bandwidth...
Autores principales: | , , , , , , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2006
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/972689 |
Sumario: | The high charge (>6ìC) electron beam produced in the CLIC Test Facility 3 (CTF3) is accelerated in fully beam loaded cavities. To be able to measure the resulting strong transient effects, the time evolution of the beam energy and its energy spread must be determined with at least 50MHz bandwidth. Three spectrometer lines are installed along the linac in order to control and tune the beam. The electrons are deflected by dipole magnets onto Optical Transition Radiation (OTR) screens which are observed by CCD cameras. The measured horizontal beam size is then directly related to the energy spread. In order to provide time-resolved energy spectra, a fraction of the OTR photons is sent onto a multi-channel photomultiplier. The overall setup is described, special focus is given to the design of the OTR screen with its synchrotron radiation shielding. The performance of the time-resolved measurements are discussed in detail. Finally, the limitations of the system, mainly due to radiation problems are discussed. |
---|