Time resolved spectrometry on the CLIC Test Facility 3

The high charge (>6ìC) electron beam produced in the CLIC Test Facility 3 (CTF3) is accelerated in fully beam loaded cavities. To be able to measure the resulting strong transient effects, the time evolution of the beam energy and its energy spread must be determined with at least 50MHz bandwidth...

Descripción completa

Detalles Bibliográficos
Autores principales: Lefèvre, T, Bal, C, Braun, H H, Bravin, E, Burger, S, Corsini, R, Döbert, Steffen, Dutriat, C, Tecker, F A, Urschütz, Peter, Welsch, C P
Lenguaje:eng
Publicado: 2006
Materias:
Acceso en línea:http://cds.cern.ch/record/972689
_version_ 1780910835751714816
author Lefèvre, T
Bal, C
Braun, H H
Bravin, E
Burger, S
Corsini, R
Döbert, Steffen
Dutriat, C
Tecker, F A
Urschütz, Peter
Welsch, C P
author_facet Lefèvre, T
Bal, C
Braun, H H
Bravin, E
Burger, S
Corsini, R
Döbert, Steffen
Dutriat, C
Tecker, F A
Urschütz, Peter
Welsch, C P
author_sort Lefèvre, T
collection CERN
description The high charge (>6ìC) electron beam produced in the CLIC Test Facility 3 (CTF3) is accelerated in fully beam loaded cavities. To be able to measure the resulting strong transient effects, the time evolution of the beam energy and its energy spread must be determined with at least 50MHz bandwidth. Three spectrometer lines are installed along the linac in order to control and tune the beam. The electrons are deflected by dipole magnets onto Optical Transition Radiation (OTR) screens which are observed by CCD cameras. The measured horizontal beam size is then directly related to the energy spread. In order to provide time-resolved energy spectra, a fraction of the OTR photons is sent onto a multi-channel photomultiplier. The overall setup is described, special focus is given to the design of the OTR screen with its synchrotron radiation shielding. The performance of the time-resolved measurements are discussed in detail. Finally, the limitations of the system, mainly due to radiation problems are discussed.
id cern-972689
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2006
record_format invenio
spelling cern-9726892023-07-20T15:07:18Zhttp://cds.cern.ch/record/972689engLefèvre, TBal, CBraun, H HBravin, EBurger, SCorsini, RDöbert, SteffenDutriat, CTecker, F AUrschütz, PeterWelsch, C PTime resolved spectrometry on the CLIC Test Facility 3Accelerators and Storage RingsThe high charge (>6ìC) electron beam produced in the CLIC Test Facility 3 (CTF3) is accelerated in fully beam loaded cavities. To be able to measure the resulting strong transient effects, the time evolution of the beam energy and its energy spread must be determined with at least 50MHz bandwidth. Three spectrometer lines are installed along the linac in order to control and tune the beam. The electrons are deflected by dipole magnets onto Optical Transition Radiation (OTR) screens which are observed by CCD cameras. The measured horizontal beam size is then directly related to the energy spread. In order to provide time-resolved energy spectra, a fraction of the OTR photons is sent onto a multi-channel photomultiplier. The overall setup is described, special focus is given to the design of the OTR screen with its synchrotron radiation shielding. The performance of the time-resolved measurements are discussed in detail. Finally, the limitations of the system, mainly due to radiation problems are discussed.CERN-AB-2006-079CLIC-Note-685CTF3-Note-080oai:cds.cern.ch:9726892006-07-13
spellingShingle Accelerators and Storage Rings
Lefèvre, T
Bal, C
Braun, H H
Bravin, E
Burger, S
Corsini, R
Döbert, Steffen
Dutriat, C
Tecker, F A
Urschütz, Peter
Welsch, C P
Time resolved spectrometry on the CLIC Test Facility 3
title Time resolved spectrometry on the CLIC Test Facility 3
title_full Time resolved spectrometry on the CLIC Test Facility 3
title_fullStr Time resolved spectrometry on the CLIC Test Facility 3
title_full_unstemmed Time resolved spectrometry on the CLIC Test Facility 3
title_short Time resolved spectrometry on the CLIC Test Facility 3
title_sort time resolved spectrometry on the clic test facility 3
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/972689
work_keys_str_mv AT lefevret timeresolvedspectrometryontheclictestfacility3
AT balc timeresolvedspectrometryontheclictestfacility3
AT braunhh timeresolvedspectrometryontheclictestfacility3
AT bravine timeresolvedspectrometryontheclictestfacility3
AT burgers timeresolvedspectrometryontheclictestfacility3
AT corsinir timeresolvedspectrometryontheclictestfacility3
AT dobertsteffen timeresolvedspectrometryontheclictestfacility3
AT dutriatc timeresolvedspectrometryontheclictestfacility3
AT teckerfa timeresolvedspectrometryontheclictestfacility3
AT urschutzpeter timeresolvedspectrometryontheclictestfacility3
AT welschcp timeresolvedspectrometryontheclictestfacility3