Cargando…
Room Temperature Magnetic Field Measurements as a Tool to Localize Inter-turns Electrical Short Circuits in the LHC Main Dipole coils
In this report the method for the localization of the electric shorts circuits in the main LHC dipoles using the magnetic measurements at room temperature is presented. The steps of the method are discussed, and two cases are studied in detail. A complete statistics of the 12 cases analyzed up to no...
Autores principales: | Bellesia, B, Molinari, G, Todesco, E |
---|---|
Lenguaje: | eng |
Publicado: |
2006
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/973860 |
Ejemplares similares
-
Short Circuit Localization in the LHC Main Dipole Coils by means of Room Temperature Magnetic Measurements
por: Bellesia, B, et al.
Publicado: (2006) -
Correlations between Field Quality and Geometry of Components in the Collared Coils of the LHC Main Dipoles
por: Bellesia, B, et al.
Publicado: (2004) -
Influence of Superconducting Cable Dimensions on Field Harmonics in the LHC Main Dipole
por: Bellesia, B, et al.
Publicado: (2004) -
Influence of Austenitic Steel Collar Dimensions on Magnetic Field Harmonics in the LHC Main Dipole
por: Bellesia, B, et al.
Publicado: (2005) -
Quality Control of the LHC Main Dipole Cold Mass through Magnetic Measurements at Room Temperature
por: Todesco, Ezio, et al.
Publicado: (2003)