Fault Detection and Identification Methods Used for the LHC Cryomagnets and Related Cabling
Several methods for electrical fault location have been developed and tested. As part of the electrical quality assurance program for the LHC, certain wires have to be subjected to a (high) DC voltage for the testing of the insulation. With the time difference of spark-induced electromagnetic signal...
Autores principales: | Bozzini, D, Caspers, Friedhelm, Chareyre, V, Duse, Y, Kroyer, T, López, R, Poncet, A, Russenschuck, Stephan |
---|---|
Lenguaje: | eng |
Publicado: |
2006
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/977784 |
Ejemplares similares
-
Detection and location of electrical insulation faults on the LHC superconducting circuits during hardware commissioning
por: Bozzini, D, et al.
Publicado: (2008) -
The Interconnections of the LHC Cryomagnets
por: Jacquemod, A, et al.
Publicado: (2001) -
The standard instrumentation feedthrough system for the LHC cryomagnets
por: Bozzini, Davide
Publicado: (2002) -
Ultrasound Diagnostics of the Superconducting Cable Connections between the Main Ring Magnets of LHC
por: Caspers, Friedhelm, et al.
Publicado: (2007) -
The Alignment Jacks of the LHC Cryomagnets
por: Dwivedi, J, et al.