Cargando…

Possible scenarios for the LHC injector upgrade

The possible upgrade of the LHC injector chain is a crucial step towards the LHC luminosity upgrade beyond 1034 cm-2s-1. It is also a mandatory requirement for the LHC energy upgrade well beyond the ultimate value of 7.56 TeV per beam. By pushing the accelerator parameters to the ultimate performanc...

Descripción completa

Detalles Bibliográficos
Autor principal: Scandale, Walter
Lenguaje:eng
Publicado: CERN 2006
Materias:
Acceso en línea:https://dx.doi.org/10.5170/CERN-2006-008.11
http://cds.cern.ch/record/978331
_version_ 1780911016574451712
author Scandale, Walter
author_facet Scandale, Walter
author_sort Scandale, Walter
collection CERN
description The possible upgrade of the LHC injector chain is a crucial step towards the LHC luminosity upgrade beyond 1034 cm-2s-1. It is also a mandatory requirement for the LHC energy upgrade well beyond the ultimate value of 7.56 TeV per beam. By pushing the accelerator parameters to the ultimate performance we can increase to 1.7×1011 the bunch population and eventually reach a peak luminosity of 2.3×1034 cm-2s-1. To go beyond, a considerable improvement of the LHC parameters, such as ß*, beam intensity, bunch length, number of circulating bunches is required. Finally, the upgrade of the injector complex and of the injection energy is another important ingredient to upgrade both peak and integrated luminosity up to an order of magnitude above the nominal value.
id cern-978331
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2006
publisher CERN
record_format invenio
spelling cern-9783312019-09-30T06:29:59Zdoi:10.5170/CERN-2006-008.11http://cds.cern.ch/record/978331engScandale, WalterPossible scenarios for the LHC injector upgradeAccelerators and Storage RingsThe possible upgrade of the LHC injector chain is a crucial step towards the LHC luminosity upgrade beyond 1034 cm-2s-1. It is also a mandatory requirement for the LHC energy upgrade well beyond the ultimate value of 7.56 TeV per beam. By pushing the accelerator parameters to the ultimate performance we can increase to 1.7×1011 the bunch population and eventually reach a peak luminosity of 2.3×1034 cm-2s-1. To go beyond, a considerable improvement of the LHC parameters, such as ß*, beam intensity, bunch length, number of circulating bunches is required. Finally, the upgrade of the injector complex and of the injection energy is another important ingredient to upgrade both peak and integrated luminosity up to an order of magnitude above the nominal value.CERNoai:cds.cern.ch:9783312006
spellingShingle Accelerators and Storage Rings
Scandale, Walter
Possible scenarios for the LHC injector upgrade
title Possible scenarios for the LHC injector upgrade
title_full Possible scenarios for the LHC injector upgrade
title_fullStr Possible scenarios for the LHC injector upgrade
title_full_unstemmed Possible scenarios for the LHC injector upgrade
title_short Possible scenarios for the LHC injector upgrade
title_sort possible scenarios for the lhc injector upgrade
topic Accelerators and Storage Rings
url https://dx.doi.org/10.5170/CERN-2006-008.11
http://cds.cern.ch/record/978331
work_keys_str_mv AT scandalewalter possiblescenariosforthelhcinjectorupgrade