Cargando…
Protection, interlocks and diagnostics
When designing any power converter it is essential to assess and incorporate adequate protection. The main objective is to offer a solution which is safe, reliable and repairable and that achieves its specification within budget. The level of protection found within each converter varies widely and...
Autores principales: | , , , |
---|---|
Lenguaje: | eng |
Publicado: |
CERN
2006
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.5170/CERN-2006-010.327 http://cds.cern.ch/record/987560 |
_version_ | 1780911258817527808 |
---|---|
author | Griffiths, S A Charnley, G White, C Theed, J E |
author_facet | Griffiths, S A Charnley, G White, C Theed, J E |
author_sort | Griffiths, S A |
collection | CERN |
description | When designing any power converter it is essential to assess and incorporate adequate protection. The main objective is to offer a solution which is safe, reliable and repairable and that achieves its specification within budget. The level of protection found within each converter varies widely and will depend on the topology employed, its application and rating. This document is a guide to the types of protection engineers should consider mainly when designing power converters, as protection added during construction or after installation will always be expensive. |
id | cern-987560 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2006 |
publisher | CERN |
record_format | invenio |
spelling | cern-9875602019-09-30T06:29:59Zdoi:10.5170/CERN-2006-010.327http://cds.cern.ch/record/987560engGriffiths, S ACharnley, GWhite, CTheed, J EProtection, interlocks and diagnosticsAccelerators and Storage RingsWhen designing any power converter it is essential to assess and incorporate adequate protection. The main objective is to offer a solution which is safe, reliable and repairable and that achieves its specification within budget. The level of protection found within each converter varies widely and will depend on the topology employed, its application and rating. This document is a guide to the types of protection engineers should consider mainly when designing power converters, as protection added during construction or after installation will always be expensive.CERNoai:cds.cern.ch:9875602006 |
spellingShingle | Accelerators and Storage Rings Griffiths, S A Charnley, G White, C Theed, J E Protection, interlocks and diagnostics |
title | Protection, interlocks and diagnostics |
title_full | Protection, interlocks and diagnostics |
title_fullStr | Protection, interlocks and diagnostics |
title_full_unstemmed | Protection, interlocks and diagnostics |
title_short | Protection, interlocks and diagnostics |
title_sort | protection, interlocks and diagnostics |
topic | Accelerators and Storage Rings |
url | https://dx.doi.org/10.5170/CERN-2006-010.327 http://cds.cern.ch/record/987560 |
work_keys_str_mv | AT griffithssa protectioninterlocksanddiagnostics AT charnleyg protectioninterlocksanddiagnostics AT whitec protectioninterlocksanddiagnostics AT theedje protectioninterlocksanddiagnostics |