Cargando…

Recommended Locations of Beam Loss Monitors for the TOTEM Roman Pots

This note presents results from simulations of losses on the TOTEM Roman Pot stations located close to 150m and 220m from IP5. These results are used to evaluate suitable locations to position beam loss monitors to monitor these losses, and help to avoid quenches of the super-conducting magnets down...

Descripción completa

Detalles Bibliográficos
Autores principales: Hall-Wilton, R J, Macina, D, Talanov, V
Lenguaje:eng
Publicado: 2006
Materias:
Acceso en línea:http://cds.cern.ch/record/990862
_version_ 1780911367280132096
author Hall-Wilton, R J
Macina, D
Talanov, V
author_facet Hall-Wilton, R J
Macina, D
Talanov, V
author_sort Hall-Wilton, R J
collection CERN
description This note presents results from simulations of losses on the TOTEM Roman Pot stations located close to 150m and 220m from IP5. These results are used to evaluate suitable locations to position beam loss monitors to monitor these losses, and help to avoid quenches of the super-conducting magnets downstream of the roman pots. The results presented in this note indicate the locations where the BLMs should be installed. A more detailed note on the topic will follow later.
id cern-990862
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2006
record_format invenio
spelling cern-9908622019-09-30T06:29:59Zhttp://cds.cern.ch/record/990862engHall-Wilton, R JMacina, DTalanov, VRecommended Locations of Beam Loss Monitors for the TOTEM Roman PotsAccelerators and Storage RingsThis note presents results from simulations of losses on the TOTEM Roman Pot stations located close to 150m and 220m from IP5. These results are used to evaluate suitable locations to position beam loss monitors to monitor these losses, and help to avoid quenches of the super-conducting magnets downstream of the roman pots. The results presented in this note indicate the locations where the BLMs should be installed. A more detailed note on the topic will follow later.LHC-Project-note-386CERN-LHC-Project-note-386oai:cds.cern.ch:9908622006-10-23
spellingShingle Accelerators and Storage Rings
Hall-Wilton, R J
Macina, D
Talanov, V
Recommended Locations of Beam Loss Monitors for the TOTEM Roman Pots
title Recommended Locations of Beam Loss Monitors for the TOTEM Roman Pots
title_full Recommended Locations of Beam Loss Monitors for the TOTEM Roman Pots
title_fullStr Recommended Locations of Beam Loss Monitors for the TOTEM Roman Pots
title_full_unstemmed Recommended Locations of Beam Loss Monitors for the TOTEM Roman Pots
title_short Recommended Locations of Beam Loss Monitors for the TOTEM Roman Pots
title_sort recommended locations of beam loss monitors for the totem roman pots
topic Accelerators and Storage Rings
url http://cds.cern.ch/record/990862
work_keys_str_mv AT hallwiltonrj recommendedlocationsofbeamlossmonitorsforthetotemromanpots
AT macinad recommendedlocationsofbeamlossmonitorsforthetotemromanpots
AT talanovv recommendedlocationsofbeamlossmonitorsforthetotemromanpots