Cargando…
Optically sensitive Medipix2 detector for adaptive optics wavefront sensing
A new hybrid optical detector is described that has many of the attributes desired for the next generation adaptive optics (AO) wavefront sensors. The detector consists of a proximity focused microchannel plate (MCP) read out by multi-pixel application specific integrated circuit (ASIC) chips develo...
Autores principales: | , , , , , |
---|---|
Lenguaje: | eng |
Publicado: |
2005
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/994211 |
_version_ | 1780911445758705664 |
---|---|
author | Vallerga, John McPhatea, Jason Tremsina, Anton Siegmund, Oswald Mikulec, Bettina Clark, Allan G |
author_facet | Vallerga, John McPhatea, Jason Tremsina, Anton Siegmund, Oswald Mikulec, Bettina Clark, Allan G |
author_sort | Vallerga, John |
collection | CERN |
description | A new hybrid optical detector is described that has many of the attributes desired for the next generation adaptive optics (AO) wavefront sensors. The detector consists of a proximity focused microchannel plate (MCP) read out by multi-pixel application specific integrated circuit (ASIC) chips developed at CERN ("Medipix2") with individual pixels that amplify, discriminate and count input events. The detector has 256 x 256 pixels, zero readout noise (photon counting), can be read out at 1 kHz frame rates and is abutable on 3 sides. The Medipix2 readout chips can be electronically shuttered down to a temporal window of a few microseconds with an accuracy of 10 ns. When used in a Shack-Hartmann style wavefront sensor, a detector with 4 Medipix chips should be able to centroid approximately 5000 spots using 7 x 7 pixel sub-apertures resulting in very linear, off-null error correction terms. The quantum efficiency depends on the optical photocathode chosen for the bandpass of interest. |
id | cern-994211 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2005 |
record_format | invenio |
spelling | cern-9942112019-09-30T06:29:59Zhttp://cds.cern.ch/record/994211engVallerga, JohnMcPhatea, JasonTremsina, AntonSiegmund, OswaldMikulec, BettinaClark, Allan GOptically sensitive Medipix2 detector for adaptive optics wavefront sensingDetectors and Experimental TechniquesA new hybrid optical detector is described that has many of the attributes desired for the next generation adaptive optics (AO) wavefront sensors. The detector consists of a proximity focused microchannel plate (MCP) read out by multi-pixel application specific integrated circuit (ASIC) chips developed at CERN ("Medipix2") with individual pixels that amplify, discriminate and count input events. The detector has 256 x 256 pixels, zero readout noise (photon counting), can be read out at 1 kHz frame rates and is abutable on 3 sides. The Medipix2 readout chips can be electronically shuttered down to a temporal window of a few microseconds with an accuracy of 10 ns. When used in a Shack-Hartmann style wavefront sensor, a detector with 4 Medipix chips should be able to centroid approximately 5000 spots using 7 x 7 pixel sub-apertures resulting in very linear, off-null error correction terms. The quantum efficiency depends on the optical photocathode chosen for the bandpass of interest.CERN-OPEN-2006-064oai:cds.cern.ch:9942112005-04-01 |
spellingShingle | Detectors and Experimental Techniques Vallerga, John McPhatea, Jason Tremsina, Anton Siegmund, Oswald Mikulec, Bettina Clark, Allan G Optically sensitive Medipix2 detector for adaptive optics wavefront sensing |
title | Optically sensitive Medipix2 detector for adaptive optics wavefront sensing |
title_full | Optically sensitive Medipix2 detector for adaptive optics wavefront sensing |
title_fullStr | Optically sensitive Medipix2 detector for adaptive optics wavefront sensing |
title_full_unstemmed | Optically sensitive Medipix2 detector for adaptive optics wavefront sensing |
title_short | Optically sensitive Medipix2 detector for adaptive optics wavefront sensing |
title_sort | optically sensitive medipix2 detector for adaptive optics wavefront sensing |
topic | Detectors and Experimental Techniques |
url | http://cds.cern.ch/record/994211 |
work_keys_str_mv | AT vallergajohn opticallysensitivemedipix2detectorforadaptiveopticswavefrontsensing AT mcphateajason opticallysensitivemedipix2detectorforadaptiveopticswavefrontsensing AT tremsinaanton opticallysensitivemedipix2detectorforadaptiveopticswavefrontsensing AT siegmundoswald opticallysensitivemedipix2detectorforadaptiveopticswavefrontsensing AT mikulecbettina opticallysensitivemedipix2detectorforadaptiveopticswavefrontsensing AT clarkallang opticallysensitivemedipix2detectorforadaptiveopticswavefrontsensing |