Cargando…
Strategy for allocating the MSD magnets and vacuum chambers
An analogous strategy as applied for the MSI septum magnets allows an optimisation of the installation of the MSD septa regarding magnet and chamber allocation. Even if the gain in aperture is small, of the order of half a millimetre, it is not negligible and- being essentially for free - should nev...
Autores principales: | Gyr, M, Goddard, B, Jeanneret, Jean Bernard, Ramberger, S |
---|---|
Lenguaje: | eng |
Publicado: |
2006
|
Materias: | |
Acceso en línea: | http://cds.cern.ch/record/998239 |