Cargando…

Qualification of Sub-atmospheric Pressure Sensors for the Cryomagnet Bayonet Heat Exchangers of the Large Hadron Collider

The superconducting magnets of the Large Hadron Collider (LHC) will be cooled at 1.9 K by distributed cooling loops working with saturated two-phase superfluid helium flowing in 107 m long bayonet heat exchangers [1] located in each magnet cold-mass cell. The temperature of the magnets could be diff...

Descripción completa

Detalles Bibliográficos
Autores principales: Jeanmonod, N, Bager, T, Casas-Cubillos, J
Lenguaje:eng
Publicado: 2006
Materias:
Acceso en línea:https://dx.doi.org/10.1063/1.2202540
http://cds.cern.ch/record/999501
_version_ 1780911648846905344
author Jeanmonod, N
Bager, T
Casas-Cubillos, J
author_facet Jeanmonod, N
Bager, T
Casas-Cubillos, J
author_sort Jeanmonod, N
collection CERN
description The superconducting magnets of the Large Hadron Collider (LHC) will be cooled at 1.9 K by distributed cooling loops working with saturated two-phase superfluid helium flowing in 107 m long bayonet heat exchangers [1] located in each magnet cold-mass cell. The temperature of the magnets could be difficult to control because of the large dynamic heat load variations. Therefore, it is foreseen to measure the heat exchangers pressure to feed the regulation loops with the corresponding saturation temperature. The required uncertainty of the sub-atmospheric saturation pressure measurement shall be of the same order of the one associated to the magnet thermometers, in pressure it translates as ±5 Pa at 1.6 kPa. The transducers shall be radiation hard as they will endure, in the worst case, doses up to 10 kGy and 10**15 neutrons·cm**-2 over 10 years. The sensors under evaluation were installed underground in the dump section of the SPS accelerator with a radiation environment close to the one expected for the LHC. The monitoring equipment was installed in a remote radiation protected area. This paper presents the results of the radiation qualification campaign with emphasis on the reliability and accuracy of the pressure sensors under the test conditions.
id cern-999501
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2006
record_format invenio
spelling cern-9995012023-05-31T13:24:31Zdoi:10.1063/1.2202540http://cds.cern.ch/record/999501engJeanmonod, NBager, TCasas-Cubillos, JQualification of Sub-atmospheric Pressure Sensors for the Cryomagnet Bayonet Heat Exchangers of the Large Hadron ColliderAccelerators and Storage RingsThe superconducting magnets of the Large Hadron Collider (LHC) will be cooled at 1.9 K by distributed cooling loops working with saturated two-phase superfluid helium flowing in 107 m long bayonet heat exchangers [1] located in each magnet cold-mass cell. The temperature of the magnets could be difficult to control because of the large dynamic heat load variations. Therefore, it is foreseen to measure the heat exchangers pressure to feed the regulation loops with the corresponding saturation temperature. The required uncertainty of the sub-atmospheric saturation pressure measurement shall be of the same order of the one associated to the magnet thermometers, in pressure it translates as ±5 Pa at 1.6 kPa. The transducers shall be radiation hard as they will endure, in the worst case, doses up to 10 kGy and 10**15 neutrons·cm**-2 over 10 years. The sensors under evaluation were installed underground in the dump section of the SPS accelerator with a radiation environment close to the one expected for the LHC. The monitoring equipment was installed in a remote radiation protected area. This paper presents the results of the radiation qualification campaign with emphasis on the reliability and accuracy of the pressure sensors under the test conditions.LHC-PROJECT-Report-980CERN-LHC-Project-Report-980oai:cds.cern.ch:9995012006-11-20
spellingShingle Accelerators and Storage Rings
Jeanmonod, N
Bager, T
Casas-Cubillos, J
Qualification of Sub-atmospheric Pressure Sensors for the Cryomagnet Bayonet Heat Exchangers of the Large Hadron Collider
title Qualification of Sub-atmospheric Pressure Sensors for the Cryomagnet Bayonet Heat Exchangers of the Large Hadron Collider
title_full Qualification of Sub-atmospheric Pressure Sensors for the Cryomagnet Bayonet Heat Exchangers of the Large Hadron Collider
title_fullStr Qualification of Sub-atmospheric Pressure Sensors for the Cryomagnet Bayonet Heat Exchangers of the Large Hadron Collider
title_full_unstemmed Qualification of Sub-atmospheric Pressure Sensors for the Cryomagnet Bayonet Heat Exchangers of the Large Hadron Collider
title_short Qualification of Sub-atmospheric Pressure Sensors for the Cryomagnet Bayonet Heat Exchangers of the Large Hadron Collider
title_sort qualification of sub-atmospheric pressure sensors for the cryomagnet bayonet heat exchangers of the large hadron collider
topic Accelerators and Storage Rings
url https://dx.doi.org/10.1063/1.2202540
http://cds.cern.ch/record/999501
work_keys_str_mv AT jeanmonodn qualificationofsubatmosphericpressuresensorsforthecryomagnetbayonetheatexchangersofthelargehadroncollider
AT bagert qualificationofsubatmosphericpressuresensorsforthecryomagnetbayonetheatexchangersofthelargehadroncollider
AT casascubillosj qualificationofsubatmosphericpressuresensorsforthecryomagnetbayonetheatexchangersofthelargehadroncollider