Cargando…

A point-to-point link for data, trigger, clock and control over copper or fibre

Upgrades of the LHC detectors target significantly higher event rates and higher bandwidth over point-to-point links. The Data, Trigger, Clock and Control (DTCC) is a new custom link protocol for data and control streams over different physical media, as copper or optical fibre. The DTCC link is imp...

Descripción completa

Detalles Bibliográficos
Autores principales: Tarazona, A, Gnanvo, K, Martoiu, S, Muller, H, Toledo, J
Lenguaje:eng
Publicado: 2014
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1748-0221/9/06/T06004
http://cds.cern.ch/record/2003111
_version_ 1780946176222167040
author Tarazona, A
Gnanvo, K
Martoiu, S
Muller, H
Toledo, J
author_facet Tarazona, A
Gnanvo, K
Martoiu, S
Muller, H
Toledo, J
author_sort Tarazona, A
collection CERN
description Upgrades of the LHC detectors target significantly higher event rates and higher bandwidth over point-to-point links. The Data, Trigger, Clock and Control (DTCC) is a new custom link protocol for data and control streams over different physical media, as copper or optical fibre. The DTCC link is implemented over 8b10b encoding. A version of the DTCC link over standard Category 6 cables is planned to be used with ALICE EMCal Calorimeters after its LS1 upgrade with a significant increase of the readout rate [1].
id oai-inspirehep.net-1301111
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2014
record_format invenio
spelling oai-inspirehep.net-13011112022-08-10T20:11:05Zdoi:10.1088/1748-0221/9/06/T06004http://cds.cern.ch/record/2003111engTarazona, AGnanvo, KMartoiu, SMuller, HToledo, JA point-to-point link for data, trigger, clock and control over copper or fibreDetectors and Experimental TechniquesUpgrades of the LHC detectors target significantly higher event rates and higher bandwidth over point-to-point links. The Data, Trigger, Clock and Control (DTCC) is a new custom link protocol for data and control streams over different physical media, as copper or optical fibre. The DTCC link is implemented over 8b10b encoding. A version of the DTCC link over standard Category 6 cables is planned to be used with ALICE EMCal Calorimeters after its LS1 upgrade with a significant increase of the readout rate [1].oai:inspirehep.net:13011112014
spellingShingle Detectors and Experimental Techniques
Tarazona, A
Gnanvo, K
Martoiu, S
Muller, H
Toledo, J
A point-to-point link for data, trigger, clock and control over copper or fibre
title A point-to-point link for data, trigger, clock and control over copper or fibre
title_full A point-to-point link for data, trigger, clock and control over copper or fibre
title_fullStr A point-to-point link for data, trigger, clock and control over copper or fibre
title_full_unstemmed A point-to-point link for data, trigger, clock and control over copper or fibre
title_short A point-to-point link for data, trigger, clock and control over copper or fibre
title_sort point-to-point link for data, trigger, clock and control over copper or fibre
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1088/1748-0221/9/06/T06004
http://cds.cern.ch/record/2003111
work_keys_str_mv AT tarazonaa apointtopointlinkfordatatriggerclockandcontrolovercopperorfibre
AT gnanvok apointtopointlinkfordatatriggerclockandcontrolovercopperorfibre
AT martoius apointtopointlinkfordatatriggerclockandcontrolovercopperorfibre
AT mullerh apointtopointlinkfordatatriggerclockandcontrolovercopperorfibre
AT toledoj apointtopointlinkfordatatriggerclockandcontrolovercopperorfibre
AT tarazonaa pointtopointlinkfordatatriggerclockandcontrolovercopperorfibre
AT gnanvok pointtopointlinkfordatatriggerclockandcontrolovercopperorfibre
AT martoius pointtopointlinkfordatatriggerclockandcontrolovercopperorfibre
AT mullerh pointtopointlinkfordatatriggerclockandcontrolovercopperorfibre
AT toledoj pointtopointlinkfordatatriggerclockandcontrolovercopperorfibre