Cargando…

CMS endcap RPC performance analysis

The Resistive Plate Chamber (RPC) detector system in LHC-CMS experiment is designed for the trigger purpose. The endcap RPC system has been successfully operated since the commissioning period (2008) to the end of RUN1 (2013). We have developed an analysis tool for endcap RPC performance and validat...

Descripción completa

Detalles Bibliográficos
Autor principal: Teng, H
Lenguaje:eng
Publicado: 2014
Materias:
Acceso en línea:https://dx.doi.org/10.1088/1748-0221/9/08/C08007
http://cds.cern.ch/record/2025771
_version_ 1780947213266976768
author Teng, H
author_facet Teng, H
author_sort Teng, H
collection CERN
description The Resistive Plate Chamber (RPC) detector system in LHC-CMS experiment is designed for the trigger purpose. The endcap RPC system has been successfully operated since the commissioning period (2008) to the end of RUN1 (2013). We have developed an analysis tool for endcap RPC performance and validated the efficiency calculation algorithm, focusing on the first endcap station which was assembled and tested by the Peking University group. We cross checked the results obtained with those extracted with alternative methods and we found good agreement in terms of performance parameters [1]. The results showed that the CMS-RPC endcap system fulfilled the performance expected in the Technical Design Report [2].
id oai-inspirehep.net-1312097
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2014
record_format invenio
spelling oai-inspirehep.net-13120972019-09-30T06:29:59Zdoi:10.1088/1748-0221/9/08/C08007http://cds.cern.ch/record/2025771engTeng, HCMS endcap RPC performance analysisDetectors and Experimental TechniquesThe Resistive Plate Chamber (RPC) detector system in LHC-CMS experiment is designed for the trigger purpose. The endcap RPC system has been successfully operated since the commissioning period (2008) to the end of RUN1 (2013). We have developed an analysis tool for endcap RPC performance and validated the efficiency calculation algorithm, focusing on the first endcap station which was assembled and tested by the Peking University group. We cross checked the results obtained with those extracted with alternative methods and we found good agreement in terms of performance parameters [1]. The results showed that the CMS-RPC endcap system fulfilled the performance expected in the Technical Design Report [2].oai:inspirehep.net:13120972014
spellingShingle Detectors and Experimental Techniques
Teng, H
CMS endcap RPC performance analysis
title CMS endcap RPC performance analysis
title_full CMS endcap RPC performance analysis
title_fullStr CMS endcap RPC performance analysis
title_full_unstemmed CMS endcap RPC performance analysis
title_short CMS endcap RPC performance analysis
title_sort cms endcap rpc performance analysis
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1088/1748-0221/9/08/C08007
http://cds.cern.ch/record/2025771
work_keys_str_mv AT tengh cmsendcaprpcperformanceanalysis