Cargando…
CMS endcap RPC performance analysis
The Resistive Plate Chamber (RPC) detector system in LHC-CMS experiment is designed for the trigger purpose. The endcap RPC system has been successfully operated since the commissioning period (2008) to the end of RUN1 (2013). We have developed an analysis tool for endcap RPC performance and validat...
Autor principal: | |
---|---|
Lenguaje: | eng |
Publicado: |
2014
|
Materias: | |
Acceso en línea: | https://dx.doi.org/10.1088/1748-0221/9/08/C08007 http://cds.cern.ch/record/2025771 |
_version_ | 1780947213266976768 |
---|---|
author | Teng, H |
author_facet | Teng, H |
author_sort | Teng, H |
collection | CERN |
description | The Resistive Plate Chamber (RPC) detector system in LHC-CMS experiment is designed for the trigger purpose. The endcap RPC system has been successfully operated since the commissioning period (2008) to the end of RUN1 (2013). We have developed an analysis tool for endcap RPC performance and validated the efficiency calculation algorithm, focusing on the first endcap station which was assembled and tested by the Peking University group. We cross checked the results obtained with those extracted with alternative methods and we found good agreement in terms of performance parameters [1]. The results showed that the CMS-RPC endcap system fulfilled the performance expected in the Technical Design Report [2]. |
id | oai-inspirehep.net-1312097 |
institution | Organización Europea para la Investigación Nuclear |
language | eng |
publishDate | 2014 |
record_format | invenio |
spelling | oai-inspirehep.net-13120972019-09-30T06:29:59Zdoi:10.1088/1748-0221/9/08/C08007http://cds.cern.ch/record/2025771engTeng, HCMS endcap RPC performance analysisDetectors and Experimental TechniquesThe Resistive Plate Chamber (RPC) detector system in LHC-CMS experiment is designed for the trigger purpose. The endcap RPC system has been successfully operated since the commissioning period (2008) to the end of RUN1 (2013). We have developed an analysis tool for endcap RPC performance and validated the efficiency calculation algorithm, focusing on the first endcap station which was assembled and tested by the Peking University group. We cross checked the results obtained with those extracted with alternative methods and we found good agreement in terms of performance parameters [1]. The results showed that the CMS-RPC endcap system fulfilled the performance expected in the Technical Design Report [2].oai:inspirehep.net:13120972014 |
spellingShingle | Detectors and Experimental Techniques Teng, H CMS endcap RPC performance analysis |
title | CMS endcap RPC performance analysis |
title_full | CMS endcap RPC performance analysis |
title_fullStr | CMS endcap RPC performance analysis |
title_full_unstemmed | CMS endcap RPC performance analysis |
title_short | CMS endcap RPC performance analysis |
title_sort | cms endcap rpc performance analysis |
topic | Detectors and Experimental Techniques |
url | https://dx.doi.org/10.1088/1748-0221/9/08/C08007 http://cds.cern.ch/record/2025771 |
work_keys_str_mv | AT tengh cmsendcaprpcperformanceanalysis |