Trigger-Induced Mechanical Resonances of Gating Grid Wires in the Multi-Wire Proportional Chambers of the ALICE TPC

A crucial issue in the design of modern multi-wire proportional chambers (MWPCs) is to avoide mechanical instabilities of thin and long wires that are held at high potentials [1]. Still, these structures are mechanically very sensitive and event-related (random) oscillations have been reported for d...

Descripción completa

Detalles Bibliográficos
Autores principales: Horn, C J, Junique, A, Lippmann, C, Mager, M, Musa, L, Richert, T
Lenguaje:eng
Publicado: 2012
Materias:
Acceso en línea:https://dx.doi.org/10.1016/j.phpro.2012.02.395
http://cds.cern.ch/record/2103400
_version_ 1780948800826769408
author Horn, C J
Junique, A
Lippmann, C
Mager, M
Musa, L
Richert, T
author_facet Horn, C J
Junique, A
Lippmann, C
Mager, M
Musa, L
Richert, T
author_sort Horn, C J
collection CERN
description A crucial issue in the design of modern multi-wire proportional chambers (MWPCs) is to avoide mechanical instabilities of thin and long wires that are held at high potentials [1]. Still, these structures are mechanically very sensitive and event-related (random) oscillations have been reported for drift tubes [2,3], where the gas ionisation originates the driving force.
id oai-inspirehep.net-1313377
institution Organización Europea para la Investigación Nuclear
language eng
publishDate 2012
record_format invenio
spelling oai-inspirehep.net-13133772022-08-10T20:15:46Zdoi:10.1016/j.phpro.2012.02.395http://cds.cern.ch/record/2103400engHorn, C JJunique, ALippmann, CMager, MMusa, LRichert, TTrigger-Induced Mechanical Resonances of Gating Grid Wires in the Multi-Wire Proportional Chambers of the ALICE TPCDetectors and Experimental TechniquesA crucial issue in the design of modern multi-wire proportional chambers (MWPCs) is to avoide mechanical instabilities of thin and long wires that are held at high potentials [1]. Still, these structures are mechanically very sensitive and event-related (random) oscillations have been reported for drift tubes [2,3], where the gas ionisation originates the driving force.oai:inspirehep.net:13133772012
spellingShingle Detectors and Experimental Techniques
Horn, C J
Junique, A
Lippmann, C
Mager, M
Musa, L
Richert, T
Trigger-Induced Mechanical Resonances of Gating Grid Wires in the Multi-Wire Proportional Chambers of the ALICE TPC
title Trigger-Induced Mechanical Resonances of Gating Grid Wires in the Multi-Wire Proportional Chambers of the ALICE TPC
title_full Trigger-Induced Mechanical Resonances of Gating Grid Wires in the Multi-Wire Proportional Chambers of the ALICE TPC
title_fullStr Trigger-Induced Mechanical Resonances of Gating Grid Wires in the Multi-Wire Proportional Chambers of the ALICE TPC
title_full_unstemmed Trigger-Induced Mechanical Resonances of Gating Grid Wires in the Multi-Wire Proportional Chambers of the ALICE TPC
title_short Trigger-Induced Mechanical Resonances of Gating Grid Wires in the Multi-Wire Proportional Chambers of the ALICE TPC
title_sort trigger-induced mechanical resonances of gating grid wires in the multi-wire proportional chambers of the alice tpc
topic Detectors and Experimental Techniques
url https://dx.doi.org/10.1016/j.phpro.2012.02.395
http://cds.cern.ch/record/2103400
work_keys_str_mv AT horncj triggerinducedmechanicalresonancesofgatinggridwiresinthemultiwireproportionalchambersofthealicetpc
AT juniquea triggerinducedmechanicalresonancesofgatinggridwiresinthemultiwireproportionalchambersofthealicetpc
AT lippmannc triggerinducedmechanicalresonancesofgatinggridwiresinthemultiwireproportionalchambersofthealicetpc
AT magerm triggerinducedmechanicalresonancesofgatinggridwiresinthemultiwireproportionalchambersofthealicetpc
AT musal triggerinducedmechanicalresonancesofgatinggridwiresinthemultiwireproportionalchambersofthealicetpc
AT richertt triggerinducedmechanicalresonancesofgatinggridwiresinthemultiwireproportionalchambersofthealicetpc